![A-Link IPC3 Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/a-link/ipc3/ipc3_user-manual_446758052.webp)
SecuGuard Basic V.5
1. Main-console
51
1.5.11 Record Setting:
When set to Motion detection or DI detection
record mode, user can set the Pre-Alarm second(s)
which the recorded file will keep a slice of image
defined as the setting second(s) before event was
triggered.
Set the Post-Alarm second(s) which the recorded file will keep a slice of image
defined as the setting second(s) after the event was triggered.
1.5.12 Motion
Configuration:
Motion detect area:
Default
button:
Select the full image for motion detection.
Add button:
Define a rectangle area on the image first, then click “Add” button to add
a new region.
Delete button:
Define a rectangle area on the image first, then click “Delete” button to
remove the region that was defined.
Sensitivity:
Set sensitivity level of motion detection. Level 5 means the highest motion
detection sensitivity. On the contrary, level 1 is the lowest level of sensitivity.
Motion
Interval:
Set this value to define the interval of motion detection. If set longer value,
means system will use less CPU computing power to check motion detection.