UNIVERSAL TOASTER UTX-200
11
P/N 1010904 Rev. 14 04/06
McDonald’s
OPERATION (continued)
Universal Toaster Settings
The following tables shows the recommended settings
for the UTX-200 Universal Toaster:
LUNCH
Setting
Value (Mfg.
Nos 9210800 &
802)
Value (Mfg.
No. 9210810)
Bun Thickness
Compression Control
knob
3
3
Platen Temperature
570° F
570° F
IR Percent Upper
60%
60%
IR Percent Lower
0%
0%
Lunch Speed
(17 Seconds)
6480
5280
MUFFIN
Setting
Value (Mfg.
Nos 9210800
& 802
Value (Mfg.
No. 9210810)
IR Percent Upper
80%
80%
IR Percent Lower
50%
50%
Muffin toasting speed
(95 seconds).
200
180
BAGEL
Setting
Value (Mfg.
Nos 9210800
& 802
Value (Mfg.
No. 9210810)
IR Percent Upper
80%
80%
IR Percent Lower
50%
50%
Bagel toasting speed
(55 seconds)
340
280
NOTE: It is recommended that these settings
remain unchanged.
The Bagel and Muffin Program use the following three
settings:
• Speed
• IR Lower%
• IR Upper %
The Lunch Program uses the following four settings:
• Speed
• Platen Temp
• IR Lower %
• IR Upper %
UTX-200 Unit Status Mode
This mode provides feedback on how the unit systems
are performing. No adjustments can be made in this
mode. Also, the display will remain on the selected
screen in this mode until you switch screens or exit Unit
Status Mode.
Press the
PRGM
button once to exit Unit Status Mode
and return to the current operation mode screen.
Follow these steps to view the Unit Status mode.
1. From any operation mode (
Bagel Ready
,
Bagel
Wait
,
Muffin Ready
,
Muffin Wait
,
Lunch
Ready
or
Lunch Wait
), open the Front Cover
and press and hold the ADJUST button for 3 sec-
onds.
2. The following appears on the display in sequence
(use the
NEXT
and
PREV
buttons to scroll
through these items):
•
Temp-Platen-Set Pt
•
Total Hours
•
Over Temp Sense
(temperature of the air com-
ing out of the blower)
• Ambient (air temperature inside the electrical
enclosure)
•
Fan Speed % of Normal
L: (Left Fan), C: (Center Fan), R: (Right Fan)
• Speed-Motor-Set-Pt
•
Lower IR
(The set point temperature appears on
the top line. The actual temperature appears on
the lower line)
•
Upper IR
(The set point temperature appears on
the top line. The actual temperature appears on
the lower line)