RAPID TOASTER VCT-200
10
P/N 1010710 Rev. N 02/13
McDonald’s
Table 2
OPERATION (continued)
Fault Codes
OLD STYLE
CONTROL BOARD
FAULT CODE
ON DISPLAY
FAULT CODE DESCRIPTION
“HI” Flashes on
display
The platen thermocouple is disconnected
or open or the platen relay is shorted.
Call for service.
“HI” and “LO”
flashes at cold
start up
The auxiliary thermocouple is discon-
nected or open. Call for service.
“HI” and “USE”
flashes after 30
minutes of pre-
heat time
The auxiliary thermocouple is discon-
nected or open or the auxiliary relay is
shorted. Call for service.
“CHEC”
The electrical compartment ambient
temperature is above 140° F (60° C). All
heaters will shut off. Check for proper air-
flow. Call for service.
“PO”
The incoming voltage has dropped below
175 VAC. All heaters will shut off. Call for
service.
“PH”
The front and/or rear Conveyor Cover
Safety Interlock Switches are not
engaged or are open or the AC Isolator
Board or its wiring is faulty. Call for ser-
vice. Some international models only.
NEW STYLE
CONTROL BOARD
FAULT CODE
ON DISPLAY
POSSIBLE CAUSE(S)
Err 1
Failed Control Board (Call for Service)
Err 2
Failed Control Board (Call for Service)
Err 3
The programming dip switches were not
adjusted upon installation of the universal
control board. The dip switches must be
adjusted to match the toaster Mfg #. Refer
to document P/N 1011052 for specific set-
tings.
Err 4
Platen Thermocouple is shorted to chassis
ground (Call for Service)
Err 5
Platen Thermocouple is Loose or Discon-
nected or Open (Call for Service)
Err 6
Failed Control Board (Call for Service)
Err 7
Failed Control Board (Call for Service)
Err 8
Failed Control Board (Call for Service)
Err 9
The programming dip switches were not
adjusted upon installation of the universal
control board. The dip switches must be
adjusted to match the toaster Mfg #. Refer
to document P/N 1011052 for specific set
-
tings. NOTE: If the dip switches were ad-
justed correctly, then the AC Isolator Board
or its wiring is faulty. (Call for Service)
Err 10
Failed Control Board (Call for Service)
CHEC
Ambient in electrical compartment has
exceeded 140 F (60 C). Check for proper
airflow. (Call for Service)
Table 1
If the toaster control board
resembles the OLD style
shown here, refer to the
Fault Message in Table 1.
If the toaster control board
resembles the NEW style
shown here, refer to the
Fault Message in Table 2.
Содержание 9200500
Страница 25: ...RAPID TOASTER VCT 200 25 P N 1010710 Rev N 02 13 McDonald s WIRING DIAGRAMS Pictorial Wiring Diagram ...
Страница 26: ...RAPID TOASTER VCT 200 26 P N 1010710 Rev N 02 13 McDonald s HI LIMIT CONTROL Ladder Wiring Diagram ...
Страница 27: ...RAPID TOASTER VCT 200 27 P N 1010710 Rev N 02 13 McDonald s NOTES ...
Страница 28: ...RAPID TOASTER VCT 200 28 P N 1010710 Rev N 02 13 McDonald s NOTES ...