PT300, Service Manual
Rev B, October, 2000
29
Remove and replace main circuit board
Tools required
Twenty thousand pound calibration press.
8" x 8" x 2
±
.25” aluminum loading block.
8" x 8" x 0.5" rubber loading pad.
Static dissipation station.
#2 Phillips screwdriver for bezel and board mounts.
Small slotted blade screwdriver.
Torque-seal potentiometer shaft sealer.
Caution:
The following procedure must only be performed at a static controlled workstation. The
main printed circuit board is subject to damage by electrostatic discharge.
Disassembly
1) Remove all 10 bezel screws.
2) Detach keyboard assembly, unplug keyboard connector and set aside.
3) Remove 2 screws holding circuit board.
4) Remove main circuit from housing.
5) Unplug harness connector.
Assembly
1) Plug printed circuit into harness connector.
2) Place circuit board into housing. Be careful not to pinch the wires between
the battery tube and the printed circuit board.
3) Install two board mounting screws.
4) Plug in keyboard.
5) Check and adjust calibration as needed.
6) Align keyboard on housing.
7) Install 10 bezel screws.
Содержание PT300
Страница 1: ...I PT300 Service Manual A A Scales 1 813 994 3190 Fax 509 355 3498 www stainlessscales com...
Страница 45: ...PT300 Service Manual Rev B October 2000 44 Appendix B Schematics...
Страница 46: ...PT300 Service Manual Rev B October 2000 45...
Страница 47: ...PT300 Service Manual Rev B October 2000 46...
Страница 48: ...PT300 Service Manual Rev B October 2000 47 Totalizing cable...
Страница 49: ...PT300 Service Manual Rev B October 2000 48 Charging Cable...
Страница 50: ...PT300 Service Manual Rev B October 2000 49 Loadcell and Summing Board...
Страница 51: ...PT300 Service Manual Rev B October 2000 50 Internal Cable Assembly...
Страница 52: ...PT300 Service Manual Rev B October 2000 51 Parts...