Connect a Juggler Optical Data Bus
Inspect before you connect
Hand-held fibre inspection microscopes may seem expensive, but prevention is cheaper than
troubleshooting, and it is essential to ensure optical connector end-faces are clean
before you
connect
. Problems arise when components are left unconnected and uncapped, so keep caps on
until the point of connection. Residues can even be present in an out-of-the-bag cable, or from the
moulded cap itself, and can transfer to a bulkhead connector.
Inspect, clean, reinspect
We recommend that the polished ends of fibre leads should be cleaned with a push-click pen
cleaner. Dry cleaning is always recommended; alcohol-based agents should
not
be used. Specialist
cleaning kits are available that ensure contaminants are not just moved about, or reintroduced by a
second use of a tool.
After cleaning, reinspect. You may still have contamination. Do not connect until you know a
connection is clean on both sides.