background image

18

M611-1 Operating Juggler 1 Pixel Processor : User Guide 

 

                                                                                         © 2022 7thSense

Rear Panel Connections

DisplayPort

 Juggler with 4 × Tx + 4 × Rx DisplayPort (Unit HDMI not enabled):

SDI

-enabled Jugglers are equipped with up to four SFP modules (shown red):

Data bus

Each Juggler has four processing channels. By bussing Jugglers together, additional processing
channels can be added to the Juggler system. To 

bus

 Juggler modules together, use optical fibre

cables. Full 8-lane bandwidth MPO I/O ports (shown yellow) may be used, or 4-lane SFP modules
(shown magenta). See also 

Connect a Juggler Data Bus

:

These are configured typically alongside 2 × DP or 2 × HDMI in the second interface.

Bus capacity

The bus configuration determines the capacity in terms of resolution and equivalent bandwidth. To
increase bandwidth, lanes 4 and 8 can share their capacity with lanes 1-3 and 5-7. Effectively this
becomes a 6-Lane ‘High Bandwidth’ bus, with lanes 4 and 8 unavailable to separate video channels.

Bits per Pixel

 determines capacity of your bus for your media requirement.

25

Содержание Juggler 1

Страница 1: ...Juggler Pixel Processor Operating Juggler 1 M611 1 User Guide...

Страница 2: ...l Rights Reserved This document is copyrighted by 7thSense Design Ltd and shall not be reproduced or copied without express written authorisation from 7thSense Design Ltd The information in this docum...

Страница 3: ...ubnet 14 Rear Panel Connections 15 Input and Output Options 17 GPIO HD BNC Ports 20 GPIO Genlock Example 21 Workflow Physical Connections 24 Connect a Juggler Optical Data Bus 25 Connecting to a Netwo...

Страница 4: ...e Compere User Guide Compere 1 0 5 User Guide Juggler is a highly modular FPGA based pixel processor providing the highest hardware performance and efficiency combined with ultimate connectivity It is...

Страница 5: ...nlocked to frame accuracy with instant system failover across all connected devices via frame data monitoring an API is available for third party sources Compere Compere pronounced KOM pair is the sof...

Страница 6: ...around dynamically such as picture in picture elements If network connection is lost by any Juggler in a Project Group the local copy of the Project will keep running until it can reconnect and re sy...

Страница 7: ...Source API available DisplayPort 1 2 12G SDI and HDMI 2 0 optional HDCP compliant DisplayPort output SST to MST conversion Supports 12 bit 4 4 4 internal processing at high precision Colourspace mappi...

Страница 8: ...ned by utilising a high capacity data bus The number and balance of inputs and outputs in a Juggler system is completely scalable Any input live capture streamed or prerecorded can be processed by any...

Страница 9: ...at demonstrate its potential roles Example 1 IntelligentSource failover Use cases Ultra reliable auto failover per input or whole system seamless source switching A large 16K 4K canvas IntelligentSour...

Страница 10: ...10 M611 1 Operating Juggler 1 Pixel Processor User Guide 2022 7thSense What Juggler Can Do...

Страница 11: ...rt the unit The power button will show a bright blue ring and the display panel will go through a start up cycle before settling to status information and the Juggler logo Reset Should you need to res...

Страница 12: ...nitoring of a single Juggler by selecting and swiping The default page that comes up on start up and to which other pages revert after 30 seconds is set in the properties of the Juggler internal Linux...

Страница 13: ...13 M611 1 Operating Juggler 1 Pixel Processor User Guide 2022 7thSense Front Panel Controls See Set Juggler Static IP and Subnet 14...

Страница 14: ...o tab if it is not already showing Swipe from right to left to move to the IP Editor page Touch to select an octet address element to change it will show highlighted blue Use the number pad on the lef...

Страница 15: ...ggler modules configured for HDMI expandable with the I O Interface panels IN RJ45 Network port LEDs on this port are inactive USB 3 0 Not used MODULE 4 numbered 1 4 options 4 SFP modules either 12G b...

Страница 16: ...Jugglers see Connect a Juggler Data Bus Half bus Important Only SFP modules approved by 7thSense should be fitted to the Juggler unit fitting non approved SFP modules may cause damage to the Juggler...

Страница 17: ...rocessing on the way These can save bandwidth by using the Bypass feature 2 Other Juggler inputs may occupy an entire video channel in which case they go directly from input port to output port 3 For...

Страница 18: ...e optical fibre cables Full 8 lane bandwidth MPO I O ports shown yellow may be used or 4 lane SFP modules shown magenta See also Connect a Juggler Data Bus These are configured typically alongside 2 D...

Страница 19: ...r Panel Connections Bus Mode Bits Per Pixel Max Resolution at 60fps or equivalent bandwidth 4 Lane Bus HD BNC SFP modules 8 Lane Bus MPO Interface 30 UHD 3840 2160 4 buses 2 2 8 buses 4 4 24 4800 2160...

Страница 20: ...d to the Juggler s video channels in the Juggler properties of Compere All Juggler ports are configured independently in Compere including GPIO See Compere User Guide GPIO Properties These GPIO ports...

Страница 21: ...source and the signal it is sending as the V Sync is is receiving from this source expressed as Rx V Sync see terms above See Compere 1 0 5 User Guide GPIO Properties The next Juggler in line has its...

Страница 22: ...Genlock Mode Now that every unit has a genlock signal each that has a signal received on its GPIO 2 can use that for the output genlock mode in Compere The first Juggler has no signal on GPIO 2 so us...

Страница 23: ...23 M611 1 Operating Juggler 1 Pixel Processor User Guide 2022 7thSense Rear Panel Connections...

Страница 24: ...ddress for the unit and the Juggler logo 5 Reassign IP addresses for each Juggler as required 6 Switch off all units 7 Connect any data bus or buses between Jugglers that will combine to form a system...

Страница 25: ...ed to be short but the minimum bend radius of a free hanging cable should be not less than 10 times the cable outside diameter This page covers the physical cabling of a single bus For an explanation...

Страница 26: ...er patch cables which will have colour or tag identifiers It can be helpful to choose an identifier to work with yellow a number etc and keep these on the outside as you work down one side and up the...

Страница 27: ...til the point of connection Residues can even be present in an out of the bag cable or from the moulded cap itself and can transfer to a bulkhead connector Inspect clean reinspect We recommend that th...

Страница 28: ...irst identify the Rx and Tx ports and in particular the numbering on the rear panel so you understand how these are represented in Compere s representations All live ports are automatically identified...

Страница 29: ...ion of Compere on a Juggler or many Jugglers in a Project Group This can be done remotely from a control PC to distribute the installer In Compere on the control PC select the required Jugglers in the...

Страница 30: ...ipt Import MPCDI Shift I Any Juggler upload an MPCDI file to the Project Admin Show Juggler Console Shift C Admin access to the Juggler TCP UDP service support console Update Firmware Shift F Juggler...

Страница 31: ...50 C Humidity non condensing 10 to 90 5 to 95 Altitude 2000 m 10000 m Specification Rating Description Notes Rackmount Dimensions H W D 1U 44 3 424 500 mm Width including mounting ears 482 6 mm Rackmo...

Страница 32: ...32 M611 1 Operating Juggler 1 Pixel Processor User Guide 2022 7thSense Juggler Physical Specifications Side panel exhaust vents mm in Rear panel exhaust vents mm in...

Страница 33: ...be secured using an M6 rack mount bolt in each of the top and bottom mounting holes on each side of the unit s front panel These ears alone will not support the weight of the unit Mount Jugglers with...

Страница 34: ...net with front or rear doors the ambient temperature around the unit may be higher than the ambient room temperature Electrical Before connecting power to the unit ensure the electricity supply is com...

Страница 35: ...s important to remove and clean or replace the filters periodically to avoid overheating Spare filter pads for Juggler units can be provided by 7thSense Juggler should not be run without filters since...

Страница 36: ...d removed can cause overheating Any alterations to the product s specification e g additional alternative components may invalidate the warranty or impact the unit s performance Additionally such chan...

Страница 37: ...the unit may be compromised leading to overheating Any alterations to the product s specification e g additional alternative components may invalidate the warranty or impact the unit s performance Add...

Страница 38: ...nst harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance wit...

Страница 39: ...Guide 2022 7thSense Document Information Document Information Date Document edition Software version Revision Details Author Editor December 2021 1 Compere 1 0 build 5 Previously published as part of...

Страница 40: ...15 genlocking via GPIO 21 GPIO ports use 20 I input output 17 input output connections 15 interconnections 17 interface options 17 J Juggler Compere systems 4 Juggler applications 9 Juggler pixel proc...

Страница 41: ......

Страница 42: ......

Страница 43: ......

Страница 44: ...LLC Michigan 7thSense LLC Orlando 2 The Courtyard Shoreham Road Upper Beeding Steyning West Sussex BN44 3TN UK T 44 0 1903 812299 332 E Lincoln Ave Suite 100 Royal Oak MI 48067 USA T 1 248 599 2717 4...