Setup Instructions for 7thSense 3D Sync using Labjack
Verifying Operation
Once the server application has restarted, reopen the 3DSync fix application.
Check that the ‘Level’ column next to the Leader and Follower(s) is changing intermittently. If either
of the ‘Level’ indicators are stuck at ‘0’ or ‘1’ then confirm that the relevant server is operating in a
stereo mode and that the LabJack cable assembly is connected to that server as detailed above.
Each Follower Server will be operating in one of 2 modes, either
in phase
or
out of phase
with the
Leader Server, this can be verified by looking at the 3DSync fix DeltaGUI and the stats on the Follower
server playback window (see illustration below). To view stats on Playback, press S on the Follower
keyboard or select ‘Show Stats’ from the DeltaGUI toolbar. The mode in use will be apparent as
follows:
Leader and Follower Server in phase
·
Leader and Follower Levels: Either simultaneously ‘1’ and ‘1’
or
‘0’ and ‘0’.
·
Follower ‘Inverted’ checkbox
un
ticked.
·
Follower stats will
not
indicate ‘Stereo eyes swapped’.
Leader and Follower Server out of phase
·
Leader and Follower Levels: Either simultaneously ‘0’ and ‘1’
or
‘1’ and ‘0’.
·
Follower ‘Inverted’ checkbox ticked.