6.4
Configure the IP Address of the Nodes
When the modules are shipped from the factory they will all have the same IP
address, 192.168.1.1. Prior to deploying the modules, the installer should
reprogram the IP address to a value appropriate for the network in question. The IP
address can be rewritten by following the procedure below:
By default, the management IP ip address is 192.168.1.1
To change ip address, open /etc/config/network
Modify the ip address and gateway, save it.
Then type /etc/init.d/network restart.
6.5 Image burn and upgrade
6.5.1 Burn image for first time
Connect serial cable to host board, assume boot environment is ready ( image, tftp
server and http server are ready).
On terminal of PC, when prompt press any key. Press any key to access the bios
menu.
Choose boot over Ethernet. After boot success, in terminal, type
wget2nand
http://xx.xx.xx.xx/
xx.xx.xx.xx is ip address of http server, and assume
all image are put in its root dir.
After downloaded the image, reboot the node and choose boot from NAND.
The default ip address for GWS node is 192.168.1.1
Default mode is BTS.