5.2  “Stand-by” Mode 

 

If left idle for a prolonged time the sealer will automatically switch into stand-by 
mode  (factory  set  at  60  minutes)  and  the  temperature  of  the  heating  plate  will 
be reduced to 60°C. 

When  entering  into  stand-by  mode  the  display  shows  the  decrease  of  the 
temperature in real time and the amber LED is switched off. 

The temperature of the heating element will be maintained at 60°. 

The display shows the actual temperature of the heating element and not the set 
sealing temperature. 

By  pressing  any  key  the  unit  will  automatically  begin  to  warm  up  the  heating 
plate to the pre-selected sealing temperature. 

Refer to section 4.2 to change the time after which the unit switches into stand-
by mode or to switch off the stand-by function. 

 

5.3  “Power-down” Mode 

 

If the unit remains idle in stand-by mode for a prolonged time the system will go 
into power down mode and the heating element will be switched off (factory set 
at 10 hours). The amber LED is switched off. 

The display shows the temperature decrease until it reaches 45°C, after this “LO” 
will be displayed. 

By  pressing  any  key  the  unit  will  automatically  begin  to  warm  up  the  heating 
element to the pre-selected sealing temperature. 

Refer to section 4.2 to change the time after which the unit switches into power-
down mode.  

 

5.4  Drawer Locking 

 

It  is  possible  to  lock  the  drawer  for  transport  or  when  the  unit  is  not  used  to 
prevent damage or dust contaminating the internal parts of the unit. 

To lock the drawer proceed as follows: 

• 

While pressing the 

 key close the drawer 

• 

The plate lifting platform moves up and the drawer is locked 

• 

Switch OFF the unit 

 

To unlock the drawer switch ON the unit. 

     14 

Содержание 4s2

Страница 1: ...4s2 Variable Temperature Thermal Sealer foto...

Страница 2: ...references to names or parts are purely casual and are used to illustrate the product described The document is for information only The manufacturer accepts no liability for errors contained herein...

Страница 3: ...Operating Mode 10 4 2 Set Up Stand By Power Down Buzzer 11 5 Basic Functions 12 5 1 Run Mode 12 5 2 Stand By Mode 14 5 3 Power Down Mode 14 5 4 Drawer Locking 14 6 Troubleshooting 15 6 1 Introduction...

Страница 4: ...the operator needs to position the sample plate together with a foil or film on the plate carrier The sealing operation starts once the drawer with the plate carrier has been closed Film and sample pl...

Страница 5: ...wing safety notes This product must only be used in accordance with proper safety standards and procedures together with the instructions included in this manual The sealer has been designed and manuf...

Страница 6: ...the unit is only connected to an earthed supply There are no user accessible or serviceable parts inside the unit Do not remove the unit s cabinet WARNING Hot surface The hot plate can reach temperat...

Страница 7: ...ve humidity 20 80 not condensing SET UP PARAMETERS Sealing temperature OFF or from 120 C to 200 C Step 1 C Default OFF Sealing time up to 10 seconds Step 0 5 seconds Default 3 seconds Stand by cycle n...

Страница 8: ...FICATION 2 1 Sealer Parts Casing 1 Control panel 2 Rear Power Interface 3 Heating element 4 Plate carrier 5 96well PCR Plate Adapter 6 optional Weighted platten 7 Sealing Frame 8 Chapter 2 5 2 1 3 4 5...

Страница 9: ...Control panel Figure 2 Control Panel Display Three Digit LED display Keys 1 M Set up Run mode key 2 Directional key up 3 Directional key down Led 4 Status Indicator Amber 1 2 3 4 6...

Страница 10: ...2 1 2 Rear Power Interface Figure 3 Rear Power Interface 1 Power Setting 115 230 Vac and Fuse Holder 2 I O Power Switch 3 Mains Power Plug 2 1 3 7...

Страница 11: ...ltage selector switch should be checked to ensure that the voltage has been set at the correct value Connect the unit to the mains power supply and switch on the switch I O of the rear power interface...

Страница 12: ...rewdriver lever out the fuse holder figure 3B 3 Replace the two fuses according to the table below Power Voltage EN 60127 115v 3 15A T 230v 2A T Table 4 Insert the fuse holder keeping the set voltage...

Страница 13: ...see page 20 for recommended sealing temperatures By pressing the M key again the new temperature value is stored and the sealing time can be set next The display shows the symbol t and the last set se...

Страница 14: ...n time can be set next The display shows the symbol P flashing and the last set power down time displayed as hours The power down time is the time after which the heater is switched off automatically...

Страница 15: ...n be loaded onto the standard plate carrier However for easier handling of shallow well plates we recommend to place the standard plate carrier 4ti 0615 inside the adapter for 96well PCR plates option...

Страница 16: ...stop moving An error message will be displayed and a continuous audible beep will be emitted To rectify this and to continue with the sealing process push the drawer in fully until you can a beep If...

Страница 17: ...e stand by function 5 3 Power down Mode If the unit remains idle in stand by mode for a prolonged time the system will go into power down mode and the heating element will be switched off factory set...

Страница 18: ...the low position within a defined time Er5 motor over current Er6 temperature sensor opened or disconnected Er7 open drawer sensor active during elevation movement Er8 platform in low position sensor...

Страница 19: ...supply Do not attempt to clean the unit until it has cooled down to near room temperature Release the lever on the back of the unit counterclockwise see figure The drawer can now be fully removed fro...

Страница 20: ...Reinsert the drawer into the unit Move the lever on the back of the unit clockwise to secure the drawer mechanism see figure Switch ON the unit 17 Figure 8 C Lever in open position...

Страница 21: ...should not be immersed in solvents Do not use acetone or abrasive cleaners No parts are to be autoclaved In case of radioactive spillages it is recommended to use an appropriate cleaning agent For any...

Страница 22: ...ene laminate Clear polyester polypropylene laminate Clear polymer Thin clear polymer Foil laminate Foil 8 3 Plate Carriers Accessories Standard Plate Carrier for skirted plates included product code 4...

Страница 23: ...nd temperature for a 348 Well Plate 4ti 0521 Peel Seal 175 C 3sec 175 C 2sec 4ti 0531 Pierce Seal 175 C 2 5sec 175 C 2sec 4ti 0533 Pierce Seal Strong 175 C 2 5sec 175 C 2sec 4ti 0536 Foil Seal 175 C 2...

Страница 24: ...the sealer 2 Switch off the unit 3 Pull out the drawer 4 Place card board sheet provided between the underside of the drawer and the top of the lifting platform inside the unit 5 Push drawer in Note T...

Страница 25: ...ves note of defects or non conformance during the warranty period the manufacturer will at its option repair or replace the affected product The manufacturer will provide at no additional charge parts...

Отзывы: