10 Braking

Page 9

Pro-120 controller instructions

Regenerative motor braking is integral to the Pro
series controllers, but it can be disabled (see section
17). When the demand speed is reduced below the
actual motor speed, the controller starts braking,
returning as much of the braking energy as possible
back into the battery. The rate at which the braking
acts is adjusted by means of the deceleration
adjustment.

For maximum energy recovery, use gentle braking.
Turning the speed control to zero for maximum
braking, shorts out the motor via the relays so there
is then no energy recovery.

Regenerative braking does not work well at slow
speeds, simply because it relies on the motor turning
to provide braking energy. Therefore, if the motor is
only turning slowly it cannot give a lot of braking, so
a vehicle may creep if parked on a hill. To stop this
creeping you can get motors fitted with an
electro-magnetically operated parking brake.

Parking Brake

When power is applied to this, the brake is released
and when power is removed the brake is applied by a
spring. The Pro series controllers have a circuit to

drive such a brake: power is applied to the solenoid
as demand speed is increased above zero and when
the demand speed returns to zero, power is removed.
Parking brake drive is via the 3 pin connector, shown
on the diagram ‘Features’. This should be wired as in
the first diagram.

The 3rd pin is battery negative so you can use a 3
position switch to give Release—Brake—Normal
(brake override facilities), as shown in the diagram
below.
The brake  driver will give 1 amp: if more current is
drawn the controller will shut down.

A B C

Release

Brake

Normal

To brake

1

A

B

C

shown in the ‘Connections’ diagram (page 7). For
variable cutback, you could fit a variable resistor. Or
you could use a switch to enable/disable the feature.
The level at which it works is controlled by the value
of the external resistor.
The controller cannot know the difference between a
flat battery and losses caused by very high battery
current in wiring that is too thin, so in some
applications it may have undesired effects. It can be
disabled completely by linking out the pinstrip
marked UVP on the features diagram. Spare
‘jumpers links’ are available from 4QD (

JLK-001

).

9.06

Reversing switch

Reversing switch connections are shown in the
diagram (facing). Reversing is ‘dual ramp’ which
means that, if the vehicle is reversed at speed, it
automatically slows down under control of the
deceleration ramp then, at zero speed, reverses and
speeds up under control of the acceleration ramp.
Whenever the vehicle is in reverse, a speed reduction
circuit operates, so that (if the gain adjustment has

been set up sensibly) full reverse speed is half of full
forward speed.

9.07

Half Speed Reversing

As supplied, reverse speed is half of forward speed.
If reverse speed reduction is not required it can be
disabled by moving the ‘jumper’ on the pinstrip
shown in the diagram on page 4.

9.08

Dual Ramp Reversing

It is possible to disable the ‘dual ramp’ when
reversing becomes ‘pre-select’ so that, if the reverse
switch is operated at speed, nothing will happen until
the demand speed is reduced to zero. Reversing will
now occur when the demand speed is turned up
again. In this mode a push switch can be used for
reversing: push the switch as you move the speed
control from zero to temporarily engage reverse and
release it when the vehicle is moving. Then, when
the speed control is again reduced to zero, the
controller will drop back into forward automatically.
To disengage dual ramp, remove the header
indicated on page 4.

Содержание Mark 2 Series

Страница 1: ...available either for 24v operation or for 12v operation Models can also be supplied for 36v and 48v The voltage is marked on the relays Make sure this are correct as 24v relays will not operate from 12v and 12v relays will soon burn out if used on 24v The standard model is suitable for permanent magnet or shunt wound motors Applications 4QD s Pro range of 4 quadrant controllers are well suited to ...

Страница 2: ...n and electromagnetic brake driver Many of these features can be disabled if so required The simplest configuration is shown in section 7 However because of the features and versatility of our controllers we give a lot of extra information in this manual which may make it seem to be more complicated than it is so we ve marked the more technical sections so you may ignore them Please don t be put o...

Страница 3: ...braking may have difficulty in operating as it has to overcharge the battery A similar problem exists if the battery is disconnected or the wiring faulty There are several options as to how the controller should react under such fault conditions so if in doubt ask In any case all passenger carrying vehicles should be fitted with mechanical brakes it is unwise to rely on the battery as an emergency...

Страница 4: ... Reverse Gain Accel MST RAT Decel Expansion connector HPLO Thermal sensor Trickle resistor UVP Brake drive transistor Battery Controls Parking brake Motor Motor Battery A B C D F E A B C RB1 RB2 Reverse Forward 3 Features The Pro 120 has double 9 5mm motor tabs for one or two motors and single 9 5mm battery tabs Also fitted on the battery terminals is a set of 6 3mm blades to connect a charger or ...

Страница 5: ...ter won t cause damage unless the unit is connected to the battery when electrolytic corrosion will occur See also section 15 Supply voltage 12v or 24v or 36v or 48v different models Supply current 30mA at zero speed plus power relay current Motor speed forward 0 to 100 full speed adjustable in reverse 0 to 50 full Or as forward speed On board option Output current typical Current limit 125 amps m...

Страница 6: ...ttery connectors the controller feeds current back the battery during braking and if a battery connector falls off when braking this regenerated current can pump up the voltage on the dud battery connection Although the controller is protected against damage this is not advised since control is lost The same will happen if a fuse or circuit breaker opens during braking Wire size Use heavy duty wir...

Страница 7: ...ickly disconnect the motor in an emergency Also with the motor disconnected freewheeling becomes possible It is also possible to get a battery isolator switch these are normally fitted to lorries buses and boats to isolate the battery in an emergency but this is not required as the Pro 120 has a power relay which effectively disconnects the battery except for a small bleed resistor 8 04 Battery co...

Страница 8: ...internal capacitor charging through a bleed resistor before the ignition switch is closed Beware of opening the switch when the motor is running the motor will brake to a halt more or less quickly depending on the deceleration ramp setting With the ignition off or even with the battery disconnected the relays short out the motor so free wheeling is not possible To freewheel properly the motor shou...

Страница 9: ...Connections diagram page 7 For variable cutback you could fit a variable resistor Or you could use a switch to enable disable the feature The level at which it works is controlled by the value of the external resistor The controller cannot know the difference between a flat battery and losses caused by very high battery current in wiring that is too thin so in some applications it may have undesir...

Страница 10: ... deceleration rates These are user adjustable and to get best performance from your machine you should adjust them Acceleration ramp This is shown as Accel on the Features diagram It is present to make the vehicle accelerate smoothly when the speed pot is increased suddenly so as to avoid sudden surges and shocks to the mechanics As supplied it is at half setting so that the motor takes about 3 se...

Страница 11: ...link disconnected they will be independent The two motors will perform identically but with independent current limits If two motors are used off one single 200 amp controller then the full 200 amps current is available to drive either motor in stall conditions With the Pro 120 each motor may only draw up to 120 amps limited by its own controller The system therefore offers more protection to the ...

Страница 12: ... extra holes in the base swarf could get into the controller and this will invalidate any warranty 13 Heat Heatsinking The long time current the controller can give is limited by the build up of heat in the heatsink The controller will give over 110 amps for one minute this is limited by the heatsink and by heating in the printed wiring relays and other components For periods of more than a minute...

Страница 13: ...Page 13 Pro 120 controller instructions 113 9 181 166 121 118 0 0 3 15 47 8 73 2 A A B B B B 50 60 5 C 126 C ...

Страница 14: ...ession capacitor a ceramic type of 10n value is ideal If the motor does not include this you are advised to fit one across the brushes as close as possible to the motor body The controller will work without this capacitor but fitting it can lengthen the life of the system A word of warning many car type motors have the chassis connected to one terminal Take great care with these as you could easil...

Страница 15: ...damage to the controller is there is an external wiring fault There are three special sections of track which should blow if a major fault occurs in the controls or the brake connected to the 6 pin and 3 pin input connectors They are situated beneath the input connectors on the back of the board They are thin waists in the track and are is as shown arrowed in the diagram above If one fuses solder ...

Страница 16: ... the drive MOSFETs cause their drive resistors to burn up a sure sign the MOSFET has failed Relay drop out A flat battery or wiring which is too thin can cause excessive voltage drop If the supply voltage gets to low then on the 24v controllers the battery discharge protection operates and reduces controller performance On the 12v controllers discharge protection is not fitted as standard so the i...