background image

JSK-120 V1.0  05/21 

Page 2  

©4QD Ltd www.4qd.co.uk 

2.  Mounting 

The JSK-120 requires a 47mm diameter hole in the mounting panel. There is no 
limitation on the panel thickness. 

3.  Connections 

The JSK-120 uses the Vishay 981HE sensor and the wiring colours are somewhat 
counter intuitive

…. 

 

Green = +5V 

 

Red = Signal 

 

Yellow = Ground [0V] 

These should be connected to the Pro-160 / 360 control board as follows. 

 

4.  Calibration 

The Pro-

160 / 360 should have the throttle setting / input mode set to “volt”. 

If the center detent is being kept, joystick mode should be set to “on”.  
The pot learn procedure should then be carried out as described in the 
controller manual.  

 

 

Содержание JSK-120

Страница 1: ...nnections 2 4 Calibration 2 5 Disassembly 3 1 Description The JSK 120 is a single axis joystick designed for use with our Pro 160 360 series controllers It has a hall effect sensor for long life It has a removable detent to identify the center off position It has a removable end stop to limit the travel to 120 degrees All parts are replaceable ...

Страница 2: ...1HE sensor and the wiring colours are somewhat counter intuitive Green 5V Red Signal Yellow Ground 0V These should be connected to the Pro 160 360 control board as follows 4 Calibration The Pro 160 360 should have the throttle setting input mode set to volt If the center detent is being kept joystick mode should be set to on The pot learn procedure should then be carried out as described in the co...

Страница 3: ... the collar hole into the drum grub screw 2 Undo the M4 handle retaining screw 3 Place the JSK 120 handle side down and lift off the collar drum sensor assembly Take care to retain the ball bearing spring and serrated washer 4 Loosen the drum grub screw and the sensor holding screws then separate the parts Collar Handle Drum Sensor Lever ...

Страница 4: ...o the bearing surfaces of the drum and insert it into the collar with the grub screw aligning with the hole Insert an allen key through the hole into the grub screw 4 Place the collar and drum assembly onto the handle 5 Carefully pick up all three parts and tighten the handle retaining screw 6 Insert the sensor shaft into the drum the wires should be at the top nearest to the grub screw the shaft ...

Отзывы: