29
MAINTENANCE AND INSPECTION
Storing
- When not in use of an extended period, apply a thin coat of the lubricant to the steel parts to
avoid rust.
- The nailer should be stored in a warm and dry place when not in use. Do not store the nailer in
a cold weather environment.
PROBLEM
CAUSE
CORRECTION
TRIGGER VALVE
LELAKS AIR
O-RING may be
CRACKED
REPLACE O-RING
NOSE LEAKS AIR
O-RING OR GASKET
IS CUT
REPLACE O-RING OR GASKET
OR CRACKED
,
BUMPER CRACKED
/WORN
REPLACE BUMPER
FAILURE TO
CYCLE
AIR SUPPLY
RESTRICTION
CHECK AIR SUPPLY EQIPMENT
TOOL DRY
,
LACK OF
LUBRICATION
USE AIR TOOL LUBRICANT.
BROKEN CYLINDER
CAP SPRING
REPLACE CYLINDER CAP SPRING
LACK OF POWER
AIR PRESSURE TOO
LOW
CHECK AIR SUPPLY EQPMENT
SLOW TO CYCLE
BROKEN CYLINDER
CAP SPRING
REPLACE CAP SPRING
O-RINGS/SEALS CUT
OR CRACKED
REPLACE O-RINGS/SEALS
EXHAUST BLOCKD
CHECK BUMPER, HEAD VALUE
SPRING
TOOL DRY, LACK OF
LUBRICATION
USE AIR TOOL LUBRICANT.
NAILS JAM IN
TOOL
BENT NAILS
REPLACE WITH THE NEW NAILS
BROKEN/CHIPPED
PISTON
REPLACE DRIVER
WRONG SIZE NAIL
REPLACE WITH CORRECT NAIL
A qualified person should perform repair and maintenance
WARNING!
Disconnect tool from air supply before repairing the tool.
All the repairs shall be performed by qualified specialist or authorized service.
.