Hardware Overview of OWL530 

 
OWL530

 

 

 
 
 
 
 
 
 

 

 

 

 

Ventilation Valve

 

Due to extreme weather conditions, water vapor in the OWL530 

may condense. The valve allows ventilation to prevent moisture 

buildup within the OWL530. 

Ground Connector 

For connecting the ground wire. 

PoE Connector

 

For connecting to the Power Sourcing Equipment (PSE). 

N-type Connector x 2

 

For connecting to an antenna   

4 (1) is the primary antenna connector and 4 (2) is the secondary. 

Utilize both connectors for 802.11n MIMO optimized performance. 

 
Parts

 

 
 
 
 
 
 
 
 
 
 
 

 

Hardware overview of OWL530

 

 
OWL530 

Detachment Tool

 

For detaching the RJ45 connector from the PoE Port   

Pole Mount Kit 

Includes two U-shaped bolts, 8 hex nuts and 8 split washers 

Ground Wire

 

For ground connection as mentioned in 

 

Содержание EAP210

Страница 1: ...EAP210 or OWL530 Handbook ...

Страница 2: ...u may not copy reproduce distribute publish display perform or modify any part of this publication in any form or by any means without prior written permission from 4IPNET INC You may not alter or remove any copyright or other notice from copies of the content All other brand and product names are claimed or registered marks of their respective companies or organizations All rights reserved To dow...

Страница 3: ...e separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help The device contains a low power transmitter which will send out Radio Frequency RF signal when transmitting This equipment complies with FCC RF radiation exposure limits set forth f...

Страница 4: ... the radiating antenna can be kept 20 cm from nearby person in normal operation condition to meet regulatory RF exposure requirement 3 External antenna Use only the antennas which have been approved by the applicant The non approved antenna s may produce unwanted spurious or excessive RF transmitting power which may lead to the violation of VZ9130002 limit and is prohibited 4 Installation procedur...

Страница 5: ...4 6 EN 61000 4 11 Safety EN 60950 1 A11 Caution This declaration is only valid for configurations combinations of software firmware and hardware provided and supported by 4ipnet Inc The use of software or firmware not provided and supported by 4ipnet Inc may result in the equipment no longer being compliant with the regulatory requirements European standards dictate maximum radiated transmit power...

Страница 6: ... for forming a wider wireless network coverage EAP210 or OWL530 also features multiple ESSIDs with VLAN tags and multiple Virtual APs great for enterprise applications such as separating traffic from different departments using different ESSIDs The PoE LAN port is able to receive power from Power over Ethernet PoE sourcing devices Its metal case is IP68 which means that the is well suited to WLAN ...

Страница 7: ...Quick Installation Guide EAP210 or OWL530 Enterprise Access Point ENGLISH 2 Hardware Overview of EAP210 Front Panel Figure 1 EAP210 Front Panel Rear Panel 1 1 2 3 7 1 2 4 5 6 Figure 2 EAP210 Rear Panel ...

Страница 8: ...e set up 5 Restart Button Press to restart the system 6 LED Indicators Power On indicates power on Status On indicates the system is ready WLAN On indicates wireless network interface is ready for service WES For indicating WDS connection status Master Press for more than 3 seconds Slave Press once and then release right away WES Start LED Green OFF and then BLINKING SLOWLY LED Green BLINKS SLOWLY...

Страница 9: ...nd Connector For connecting the ground wire 3 PoE Connector For connecting to the Power Sourcing Equipment PSE 4 N type Connector x 2 For connecting to an antenna 4 1 is the primary antenna connector and 4 2 is the secondary Utilize both connectors for 802 11n MIMO optimized performance Parts Hardware overview of OWL530 OWL530 5 Detachment Tool For detaching the RJ45 connector from the PoE Port 6 ...

Страница 10: ...tallation Steps Step 1 Connect two N type antennas to the N type connectors Step 2 Connect one end of an Ethernet cable to the PSE POWER DATA OUT to the PSE and one end to the OWL530 Inserting the RJ45 connector to the OWL530 Unscrew the cap on the PoE Port C Insert the RJ45 cable through the outer opening of cap C Insert the RJ45 connector and wrap A around the Ethernet cable through the slit bet...

Страница 11: ...Quick Installation Guide EAP210 or OWL530 Enterprise Access Point ENGLISH Copyright 4IPNET INC All rights reserved 6 Wrap B around A through the slit on B Insert Parts A and B together into the PoE Port ...

Страница 12: ...o the PSE Step 5 Power on the PSE in order to supply power to the OWL530 Mounting the OWL530 The diameter of poles mountable by the OWL530 mounting kit is from 40mm 60mm Step 1 Screw nuts onto the U shaped bolts and insert bolts through the split washers Step 2 Align the front of OWL530 with the pole and insert the U shaped bolts into the 4 holes on the corners of the OWL530 Note Please do NOT rem...

Страница 13: ...stallation Guide EAP210 or OWL530 Enterprise Access Point ENGLISH Copyright 4IPNET INC All rights reserved 8 Step 3 Secure the OWL530 by screwing on the nuts after the inserting the washers for all four corners ...

Страница 14: ...P Segment Setup for Administrator PC Set a static IP address on the same subnet mask as the AP in TCP IP of the administrator PC such as the following example Do not duplicate the IP address used here with the IP address of the APor any other devices within the same network Example of IP Segment The valid range of IP address is 1 254 However 1 must be avoided as it is already used by the AP Below ...

Страница 15: ...0 Enterprise Access Point ENGLISH Copyright 4IPNET INC All rights reserved 10 Step 3 System Login The system manager Login Page will then appear Enter admin in the User name field and admin in the Password field and then click Login to log in ...

Страница 16: ...ccess After a successful login to EAP210 or OWL530 a System Overview page of web management interface will appear To logout simply click on the Logout button at the upper right hand corner of the interface Note AP mode is the default mode The administrator must access the system via the AP mode login page first before switching modes ...

Страница 17: ... Copyright 4IPNET INC All rights reserved 12 Common Settings Step 1 Mode Confirmation Ensure the Operating Mode is currently in AP mode Click on the Status button and then select the System Overview tab The Operating Mode is at the System section on the System Overview page ...

Страница 18: ...Quick Installation Guide EAP210 or OWL530 Enterprise Access Point ENGLISH Copyright 4IPNET INC All rights reserved 13 ...

Страница 19: ...t ENGLISH Copyright 4IPNET INC All rights reserved 14 Step 2 Change Password Click on the Utilities button and then select the Password tab Enter a new password in the New Password field and retype it in the Re enter New Password field Click SAVE to save the changes ...

Страница 20: ...ht 4IPNET INC All rights reserved 15 Step 3 Network Settings Example Settings Click on the System button and then select the Network Interface tab Click the Static radio button and enter the related information in the fields marked with red asterisks Click SAVE to save the settings ...

Страница 21: ... select the General tab Band Select an appropriate band from the drop down list box Click on the Wireless button and select the VAP Config tab ESSID Enter respective ESSID for each VAP in the ESSID field or use the default ESSID Extended Service Set Identifier is a unique identifier used for networking devices to get associated with th AP Click SAVE to save the settings ...

Страница 22: ... 1 and WEP Enter the information required in the blank fields Click SAVE to save all settings configured so far all updated settings will take effect upon reboot Congratulations The EAP210 or OWL530 is now successfully configured After OWL530 s network configuration completes please remember to change the IP Address of your PC Connection Properties back to its original settings in order to ensure ...