4B - W4005 BÜHLER ELEVATOR MONITORING SYSTEM R9.6 – 22 May 2020
Page
19
of
48
9.6.1.
Sensor Operation
This is an electronic limit switch. The sensor reacts to pressure applied to the sensor face. If the
pressure is
higher than 3.6kg
, then the sensor switches the relay to an
alarm condition
(see Figure 9). If the sensor is
correctly powered, working and no pressure is applied to the sensor face then the sensor will energize the
relay and indicate the OK state by a lit-up LED (see Figure 8).
NOTE:
TouchSwitch
TM
is delivered factory pre-calibrated and no sensitivity adjustment is possible. The sensor
is calibrated to switch to the alarm state when pressure exceeds 3.6kg. Should you require adjusting this
value, please contact your 4B Representative for more information.
Blue
White
Orange
RED LED ON
Sensor Powered and No Pressure is Applied
No
Pressure
Applied
Sensor
Face
Blue
White
Orange
RED LED OFF
Pressure is applied or No Power or Sensor Faulty
Sensor
Face
Pressure
Applied
Figure 8 - TouchSwitch in OK Condition
Figure 9 - TouchSwitch in Alarm Condition