8.1.2.
TouchSwitch Mounting Diagrams
8.1.2.1.
Typical Mounting Positions on a Bucket Elevator
Touchswitch™ must be installed above the
head
shaft between the 9 o’clock and 3
o’clock position and as close to the 3
o’clock as possible.
Note
: mount pair of TouchSwitches directly
across from each other on right and left
side of bucket elevator.
Mount T
ouchswitch™ on upside of leg
(if possible) at the highest point that the
bootshaft can be adjusted to.
Figure 4 – Touchswitch Mounting Positions – Elevator Leg