PAGE 5

3.  SELECT A QUALIFIED AND COMPETENT INSTALLER

Correct installation of the product is important for safety and performance.  If you have 

not asked 4B to perform the installation of the unit on your behalf, it is critical for the 

safety of your operation and those who may perform work on your operation that you 

select a qualified and competent electrical installer to undertake the installation.  The 

product must be installed properly to perform its designed functions.  The installer should 

be qualified, trained, and competent to perform the installation in accordance with Local 

and National Electrical Codes, all relevant OSHA Regulations, as well as any of your 

own standards and preventive maintenance requirements, and other product installation 

information supplied with the product.  You should be prepared to provide the installer 

with all necessary installation information to assist in the installation.

4.  ESTABLISH AND FOLLOW A REGULAR MAINTENANCE AND INSPECTION 

SCHEDULE FOR YOUR 4B PRODUCTS

You should develop a proper maintenance and inspection program to confirm that your 

system is in good working order at all times.  You will be in the best position to determine 

the appropriate frequency for inspection.  Many different factors known to the user will 

assist you in deciding the frequency of inspection.  These factors may include but are not 

limited to weather conditions; construction work at the facility; hours of operation; animal 

or insect infestation; and the real-world experience of knowing how your employees 

perform their jobs.  The personnel or person you select to install, operate, maintain, 

inspect or perform any work whatsoever, should be trained and qualified to perform these 

important functions.  Complete and accurate records of the maintenance and inspection 

process should be created and retained by you at all times.

5.  RETAIN AND REFER TO THE OPERATION MANUAL FOR 4B’S SUGGESTED 

MAINTENANCE AND INSPECTION RECOMMENDATIONS

As all operations are different, please understand that your specific operation may require 

additional adjustments in the maintenance and inspection process essential to permit 

the monitoring device to perform its intended function.  Retain the Operation Manual 

and other important maintenance and service documents provided by 4B and have 

them readily available for people servicing your 4B equipment.  Should you have any 

questions, please call the free 24-hour hotline number (309-698-5611).

6.  SERVICE REQUEST

If you have questions or comments about the operation of your unit or require the unit to 

be serviced please contact the 4B location who supplied the product or send your request 

via fax (309-698-5615) or call us via our 24-hour hotline number in the USA (309-698-

5611).  Please have available product part numbers, serial numbers, and approximate 

date of installation.  In order to assist you, after the product has been placed into service, 

complete the online product registration section which is accessed via our website    

www.go4b.com/usa.

Содержание M800 Elite Series

Страница 1: ...www go4b com usa M800 Elite Speed Switch MULTI VOLTAGE UNDERSPEED MONITOR INSTALLATION INSTRUCTIONS OPERATION MANUAL Part No s M8001V10C M8002V10C APPROVED Class II Div 1 C US...

Страница 2: ......

Страница 3: ...TALLATION Page 7 STANDARD WIRING DIAGRAM Page 8 SENSOR CALIBRATION Page 9 TESTING COMMISSIONING Page 10 TROUBLESHOOTING GUIDE Page 10 PRODUCT WARRANTY Page 11 TABLE OF CONTENTS Rotating parts can crus...

Страница 4: ...asked 4B to perform these tasks B All installation and wiring must be in accordance with Local and National Electrical Codes and other standards applicable to your industry Please see the article Haz...

Страница 5: ...tion work at the facility hours of operation animal or insect infestation and the real world experience of knowing how your employees perform their jobs The personnel or person you select to install o...

Страница 6: ...ICATIONS Supply 24 240 VAC VDC multi voltage universal supply Fusing Supply to be fused at 5A maximum Speed Range 10 3 600 PPM pulses per minute Sensing Range Ferrous target 11 32 9 mm maximum Non fer...

Страница 7: ...ypical mounting methods are shown in fig 4 page 9 When mounted against a solid steel shaft the target or bolt head should protrude from the shaft about 3 8 inch 10 mm Otherwise the sensor will not be...

Страница 8: ...ree and there is no connection between L and the relay until links are installed as required see figures 2 and 3 Cable length can be extended to virtually any distance required The sensor is well prot...

Страница 9: ...start up delay has been achieved 5 The green set LED will flash to echo back the set time and will automatically calibrate the alarm and shutdown speeds When the calibration is complete the green set...

Страница 10: ...e between the target stud or bolt head and sensing face of M800 Elite is within the minimum distance specified 3 Start up machine and wait for start up delay to complete set LED will be solid green 4...

Страница 11: ...UCT MISUSE ABUSE OR MISAPPLICATIONS AS AUTHORIZED BY LAW 4B SPECIFICALLY DISCLAIMS ALL WARRANTIES THAT THE PRODUCT IS FIT OR MERCHANTABLE FOR A PARTICULAR PURPOSE 3 NO WARRANTY BY SAMPLE OR EXAMPLE AL...

Страница 12: ...ica Tel 27 0 11 708 6114 Fax 27 0 11 708 1654 4B AUSTRALIA Unit 1 18 Overlord Place Acacia Ridge Queensland 4110 Australia Tel 61 0 7 3711 2565 Fax 61 0 7 3711 2574 4B COMPONENTS LTD 625 Erie Avenue M...

Отзывы: