background image

PAGE 10

TROUBLESHOOTING GUIDE

FAULT

REMEDY

Set LED is Orange

Calibration not accepted, need to recalibrate sensor (see page 9).

Set LED is Red

Follow procedure “RECALIBRATION FOR A DIFFERENT SETTING”.  If the 

set LED remains red, contact 4B.

Input LED does  

not Illuminate

Check that you have a supply of the correct value across the brown and blue 

wires.  Slide a screwdriver blade across the face of the sensor, the input LED 

should flicker.  If not, contact 4B.
If the input LED does flicker, move the front face of the sensor closer to the 

target and check the target size as specified under “INSTALLATION”.

Input LED Stays  

on Permanently

Either increase the gap between the target and the shaft, or between the 

target and the sensor face.

WARNING

If the system does not immediately shutdown as expected or alarm as required, then remove the 

machine from service until the problem has been diagnosed and corrected.

TESTING AND COMMISSIONING

1.  Check that the unit is correctly installed (see standard wiring diagram).

2.  Check that the distance between the target, stud or bolt head and sensing face of M800 Elite is within  

     the minimum distance specified.

3.  Start up machine, and wait for start-up delay to complete (set LED will be solid green).

4.  4B’s 

Speed

Master™ calibration and testing device can be used to accurately test the alarm and    

     shutdown features of the M800 Elite.  A metal putty knife or a small piece of metal can be used to   

     simulate a stop motion situation by placing the metal between the sensing face of the M800 Elite and       

     the target.  After the initial start up delay, the machine should shutdown.  

SPEED

MASTER™

The 

Speed

Master™ with Pulse Pilot is the only device that 

accurately tests the calibration of a speed switch, and allows 

testing of the alarm and shutdown features of the sensor while 

installed on the machine shaft.
The 

Speed

Master™ operates in two modes.  Input mode 

is used to measure the pulse rate at normal speed.  Output 

mode will allow the user to input pulses to the sensor for 

testing purposes.

The Pulse Pilot fits between the gap between the sensor and 

the target.  The Pulse Pilot will have no effect on the operation 

of the speed switch until it is connected to the 

Speed

Master™ 

and set to “output” mode.

Patents -

US8947073

MX321802

EP26223568

Содержание M800 Elite Series

Страница 1: ...www go4b com usa M800 Elite Speed Switch MULTI VOLTAGE UNDERSPEED MONITOR INSTALLATION INSTRUCTIONS OPERATION MANUAL Part No s M8001V10C M8002V10C APPROVED Class II Div 1 C US...

Страница 2: ......

Страница 3: ...TALLATION Page 7 STANDARD WIRING DIAGRAM Page 8 SENSOR CALIBRATION Page 9 TESTING COMMISSIONING Page 10 TROUBLESHOOTING GUIDE Page 10 PRODUCT WARRANTY Page 11 TABLE OF CONTENTS Rotating parts can crus...

Страница 4: ...asked 4B to perform these tasks B All installation and wiring must be in accordance with Local and National Electrical Codes and other standards applicable to your industry Please see the article Haz...

Страница 5: ...tion work at the facility hours of operation animal or insect infestation and the real world experience of knowing how your employees perform their jobs The personnel or person you select to install o...

Страница 6: ...ICATIONS Supply 24 240 VAC VDC multi voltage universal supply Fusing Supply to be fused at 5A maximum Speed Range 10 3 600 PPM pulses per minute Sensing Range Ferrous target 11 32 9 mm maximum Non fer...

Страница 7: ...ypical mounting methods are shown in fig 4 page 9 When mounted against a solid steel shaft the target or bolt head should protrude from the shaft about 3 8 inch 10 mm Otherwise the sensor will not be...

Страница 8: ...ree and there is no connection between L and the relay until links are installed as required see figures 2 and 3 Cable length can be extended to virtually any distance required The sensor is well prot...

Страница 9: ...start up delay has been achieved 5 The green set LED will flash to echo back the set time and will automatically calibrate the alarm and shutdown speeds When the calibration is complete the green set...

Страница 10: ...e between the target stud or bolt head and sensing face of M800 Elite is within the minimum distance specified 3 Start up machine and wait for start up delay to complete set LED will be solid green 4...

Страница 11: ...UCT MISUSE ABUSE OR MISAPPLICATIONS AS AUTHORIZED BY LAW 4B SPECIFICALLY DISCLAIMS ALL WARRANTIES THAT THE PRODUCT IS FIT OR MERCHANTABLE FOR A PARTICULAR PURPOSE 3 NO WARRANTY BY SAMPLE OR EXAMPLE AL...

Страница 12: ...ica Tel 27 0 11 708 6114 Fax 27 0 11 708 1654 4B AUSTRALIA Unit 1 18 Overlord Place Acacia Ridge Queensland 4110 Australia Tel 61 0 7 3711 2565 Fax 61 0 7 3711 2574 4B COMPONENTS LTD 625 Erie Avenue M...

Отзывы: