4B ADBT2 Скачать руководство пользователя страница 4

PAGE 4

Dear 4B Customer:
Congratulations on your purchase.  4B appreciates your business and is pleased you 

have chosen our products to meet your needs.
Please read in its entirety and understand the literature accompanying the product before 

you place the product into service.  Please read the safety precautions carefully before 

operating the product.  With each product you purchase from 4B, there are some basic 

but important safety considerations you must follow to be sure your purchase is permitted 

to perform its design function and operate properly and safely, giving you many years 

of reliable service.  Please read and understand the Customer Safety Responsibilities 

listed below.  Failure to follow this safety directive and the Operation Manuals and other 

material furnished or referenced, may result in serious injury or death. 

SAFETY NOTICE TO OUR CUSTOMERS

A. 

In order to maximize efficiency and safety, selecting the right equipment for each 

operation is vital.  The proper installation of the equipment, and regular maintenance 

and inspection is equally important in continuing the proper operation and safety 

of the product.  The proper installation and maintenance of all our products is the 

responsibility of the user unless you have asked 4B to perform these tasks.

B. All installation and wiring must be in accordance with Local and National Electrical 

Codes and other standards applicable to your industry.  (Please see the article 

“Hazard Monitoring Equipment Selection, Installation and Maintenance” at www.

go4b.com.)  The installation of the wiring should be undertaken by an experienced 

and qualified professional electrician.  Failure to correctly wire any product and/or 

machinery can result in the product or machine failing to operate as intended, and can 

defeat its design function. 

C. 

Periodic inspection by a qualified person will help assure your 4B product is 

performing properly.  4B recommends a documented inspection at least annually and 

more frequently under high use conditions.

D. Please see the last page of this manual for all warranty information regarding this 

product.

CUSTOMER SAFETY RESPONSIBILITIES

1.  READ ALL LITERATURE PROVIDED WITH YOUR PRODUCT

Please read all user, instruction and safety manuals to ensure that you understand your 

product operation and are able to safely and effectively use this product.

2.  YOU BEST UNDERSTAND YOUR NEEDS

Every customer and operation is unique, and only you best know the specific needs 

and capabilities of your operation.  Please call the 24-hour hotline at 309-698-5611 for 

assistance with any questions about the performance of products purchased from 4B.  4B 

is happy to discuss product performance with you at any time.

Содержание ADBT2

Страница 1: ...www go4b com usa ADB Sensor Tester ADJUSTABLE DEPTH BEARING SENSOR TEMPERATURE TESTER OPERATION MANUAL Part No ADBT2 Batteries Not Included...

Страница 2: ......

Страница 3: ...RESPONSIBILITIES Page 4 5 PRODUCT OVERVIEW Page 6 SPECIFICATIONS Page 7 DIMENSIONS Page 7 BATTERY INSTALLATION Page 8 TESTER OPERATION Page 9 TROUBLESHOOTING GUIDE Page 12 PRODUCT WARRANTY Page 15 TA...

Страница 4: ...asked 4B to perform these tasks B All installation and wiring must be in accordance with Local and National Electrical Codes and other standards applicable to your industry Please see the article Haz...

Страница 5: ...tion work at the facility hours of operation animal or insect infestation and the real world experience of knowing how your employees perform their jobs The personnel or person you select to install o...

Страница 6: ...re monitoring system Using indirect mode allows simulated testing of NTC type sensors within the network of 4B s T500 Hotbus control unit By connecting the ADBT to a TN4 node testing of the node and t...

Страница 7: ...ecommended Temperature Control Range Direct Testing Mode 140 F to 190 F 60 C to 90 C Indirect Testing Mode 77 F to 220 F 25 C to 105 C Temperature Set Control Adjustable by 10 F or 5 C Increments Disp...

Страница 8: ...lly unplug the ribbon cable Image C and then insert the two 9 volt batteries Image B Be sure to match the and indications on the batteries with the and indications on the battery compartment To reasse...

Страница 9: ...elect F Image D If no button is pressed within two seconds after powering up the ADBT will default to the previously selected temperature setting Direct mode uses the integrated heating block within t...

Страница 10: ...open circuit with the front of the ADBT facing toward you turn the knob all the way counter clockwise until it clicks Image I For temperature range testing start in the open circuit position and then...

Страница 11: ...PAGE 11 IMAGE H Indirect Testing Mode Output Cable Plugged Into TN4 Node IMAGE I Indirect Testing Mode Temperature Simulation Control Knob CLOCKWISE...

Страница 12: ...ctioning replace 9 volt batteries Battery Low Light Indicator Heater Block not Warming Replace AA batteries ADB Sensor not Responding as Expected to Testing 1 Make sure the ADB sensor probe is securel...

Страница 13: ...PAGE 13 NOTES...

Страница 14: ...NOTES PAGE 14...

Страница 15: ...UCT MISUSE ABUSE OR MISAPPLICATIONS AS AUTHORIZED BY LAW 4B SPECIFICALLY DISCLAIMS ALL WARRANTIES THAT THE PRODUCT IS FIT OR MERCHANTABLE FOR A PARTICULAR PURPOSE 3 NO WARRANTY BY SAMPLE OR EXAMPLE AL...

Страница 16: ...ica Tel 27 0 11 708 6114 Fax 27 0 11 708 1654 4B AUSTRALIA Unit 1 18 Overlord Place Acacia Ridge Queensland 4110 Australia Tel 61 0 7 3711 2565 Fax 61 0 7 3711 2574 4B COMPONENTS LTD 625 Erie Avenue M...

Отзывы: