background image

OVERVIEW OF ZR-TIDCI.D-PV-EM

The device ZR-TIDCI.D-PV-EM, also known as "Radio Transmitter", is 
meant to connect wirelessly a Generation Meter to the IntellyGreenPV 
In-house   Display.   Its   task   is   to   count   the   pulses   generated   by   the 
Generation Meter (watt-hour measurement) and to transmit that value 
cyclically.
The ZR-TIDCI.D-PV-EM device replaces the device normally present in 
the   standard   IntellyGreenPV   Basic   kit   (coded   as   device   ZR-TIDCI-
OPT1EM). 
The   information   in   this   document,   especially   if   related   to   electrical 
wiring,   is   intended   to   replace   what   is   stated   elsewhere   in   the 
IntellyGreenPV standard documentation.
The device is supplied with antenna and a power supply cord.

The kit includes:

(1) n.1 ZR-TIDCI.D-PV-EM
(2) n.1 Antenna
(3) n.1 Power supply cord

CHARACTERISTICS OF ZR-TIDCI.D-PV-EM

Size:

53 x 110 mm x 65 mm

Weight:

100 g

Power supply:

85-250 Vac; 50/60Hz;

Connections: 

Screw Terminal

Operating Range:

-10°C ÷ +55°C; <80%

Degree of protection:

IP 30

Radio Features:
Range Indoor/Outdoor:

25m / 100m

Trasmission Power:  

10 mW (10 dBm)

Frequency:                                  

2405 -2480 MHz

Sensitivity:                                  

-97dBm

External antenna gain:

5.5 dBmi

DSSS Modulation
IEEE 802.15.4 compliant
Ember Chip EM250 
Stack Zigbee PRO Ember

ASSEMBLING THE ZR-TIDCI.D-PV-EM

The device is designed to be installed on DIN rail inside Cabinets. 
Alternatively, the device can be attached directly to the wall with 2 anchors, 
hole diameter 5mm.

DIN rail mounting:
The DIN rail mounting is standard.
The device is compatible with DIN EN 60715.

Wall mounting:
To mount the device to the wall, follow these instructions:

WIRING THE DEVICE

Caution: 

The wiring must be performed by trained personnel.

Caution: 

Connect the device to a power line adequately 

protected against short circuits and overloads exceeding the
Maximum power handling.

Caution: 

Connect the device in accordance with what established 

under national law.

Caution: 

Do not execute wiring if the device is powered.

WIRING THE DEVICE

Connections:

(A) – Bicolor Led
(B) – Disassociation Button
(C) – Antenna Connector

(5) – Counting Input
(6) – Gnd
(7) – Vcc
(8) – Alarm Input
(9) – Gnd

(17) – Power Supply 230V
(16) – Power Supply 230V

Functional Diagram

Connecting counting input to the optical interface (optional)

(5) – Counting Input – Brown  Wire
(6) – Gnd – Black Wire
(7) – Vcc – Blue Wire 

4-noks s.r.l. - Francenigo di Gaiarine (TV) Italy

(2)

(1)

Drill  two  5mm  holes  on  the  wall  at  84mm 
distance, correspondent to the notch 

A

 and 

to the hole 

B

 present on the bottom of the 

case.

Screw  a  screw  to  wall  plug 

C

,  without 

tighten,  leaving  about  2.5  mm  of  space 
between  the  head  of  screw  and  the  wall 
surface.

Place the module to the wall so that the 
screw 

C

 fits into the device's notch 

A

.

Slide the module down until you see 
through hole 

B

 the relative wall plug.

Screw the screw 

D

 tightening to ensure the 

mechanical fixing of device

(3)