WIRING THE DEVICE

Connecting counting input to a clean contact output (S0 output)

Connect S0 output to 
terminal (5) and (6)

Connecting alarm input to a clean contact output (S0 output)

Connect S0 output to 
terminal (8) and (9)

Waring:

If an optical interface is not used, make sure the counting 
input (and alarm input) is connected to outputs with voltage 
free contact. 
Do not apply differences of  potential to these terminals 
contacts.
Otherwise, the device may be damaged beyond repair.

 

OPERATING CONTROLS

Button

If pressed for longer than 10 seconds the device is reset to its original
state (disconnected device).
This action causes the loss of data relating to the radio communication
and the loss of connection with the In-house Display and all devices
connected to it.

LIGHT SIGNALS

Led State

Description

Continuous light orange. 
Short flash every 20 
seconds.

Indicates that the device is not
connected to any radio network.

Flashing Green

Flashing indicates that the
device is operating normally.

ASSOCIATION TO THE IN-HOUSE DISPLAY

Normally the device is supplied in the kit along with the In-house Display and
normally the two objects are already connected and therefore able to work
immediately after their powering, without additional configuration.
If for some reason there's no association between the two devices (because
of the disconnection of the In-house Display or Radio Transmitter) you can
connect them again.

Association of the device:

1)

Turn on In-house Display and Radio Transmitter

2)

Verify that the  Radio Transmitter  is not connected  to any  radio 
network (the LEDs are all switched on and perform a quick flash 
for  two  seconds  every  20  seconds),  otherwise  disassociate  the 
device by pressing the button for more than 10 seconds.

3)

Acting   on   the   In-house   Display,   open   the   radio   network 
(Menu/Radio   Management/   Open   Radio   Network)   following   the 
steps:

A few seconds after opening the network, the device should connect to the 
radio network of the remote display. The operation's success is highlighted 
by the flashing of led LD1 of the device.
If after 30 seconds from the opening of the network the device is still not 
connected, maybe the chosen location is not suitable; in this case place the
device   closer   to   the   In-house   Display   or   install   another   Repeater   (ZR-
REPE230M).
When finished, close the radio network via In-house Display.

STANDARDS

Regulations: 2006/95/CE, 89/336/CE, 99/5/CE
Standards:    EN 300 328, EN 301 489, EN 61000-6-2, EN 6100-6-3,
                     EN 60950-1

Disposal

In case of disposal, the products must be disposed of separately in
accordance with applicable local laws.

Warranty Conditions

The warranty period is 2 years from the date of installation or 30 months
from the date of manufacture.
The warranty applies only in UK.
The manufacturer agrees to replace or repair the components that are
found defective.
Damage caused by improper installation, by a power supply not
compliant with the CEI EN 50160 standard, by the incorrect use or
failure to comply with the instructions contained in the Assembling
Installation is not covered by the warranty.

NOTES:

4-noks s.r.l. - Francenigo di Gaiarine (TV) Italy

Confirm this request to open
the In-house Display radio
network

At the end of the association 
process, confirm this request to 
close the In-House Display 
Radio Network

Press the button under "Menu"

Select "Open Radio Network"

Select "Open Radio Network"

INSTRUCTIONS

INPV

SERIES

VERSION

DATE

001

1.4

06 / 2011

Отзывы: