Command Line Interface
www.3ware.com
14
Sample of output:
Turning the cache on for unit 0 on controller
0
set cache
disable
Example:
Escalade CLI> set cache c0 u0 off
Sample of output:
Turning the cache off for unit 0 on control-
ler 0
set rebuild
Description:
To set the rebuild rate of controller 0 to 3 (the middle value).
Example:
Escalade CLI> set rebuild c0 3
Sample of output:
Setting the rebuild rate of controller to 3
(Balanced rebuild and I/O)
Array Maintenance
The
maint command
The maint command enables a user to perform maintenance operations on
the controller, its units, and drives. It is recommended that you use the info
command first to query the controller information prior to using the maint
command. The array maintenance feature supports:
•
add - adds a drive. The new drive can be specified as a hot spare
or as a new JBOD after it is physically connected to the control-
ler. If not specified, it is added as a CBOD; a configurable JBOD
which can be used to rebuild a degraded array.