EN
Installation of Motor with built-in re Remote Rontrol Topline - Beds with
RSM functionality (position monitoring)
Please connect the remote controls correctly for a proper use of the motor with built-in
receiver.
Note: in case of a double bed;
PLEASE
install both bed parts one by one, not
together!
!
Connecting or linking of the remote control to the motor can be done in 2 different
ways:
•
Automatic connecting mode:
o
Plug the 220V power plug of the motor to the mains.
o
After connection to the main power, the white LED lights of the motor
will light up and the receiver enters in an automatic connecting mode.
(
FOR THIS REASON -in case of a double bed- PLEASE install
the bed parts one by one to avoid connection problems !!)
o
You now have
60 seconds
to connect the remote control.
o
Press the remote buttons
1
&
2
(first row) TOGETHER.
o
On the motor, the white LED flashes 2 x and goes out (the blue LED
flashes for another 60 seconds). The connection between remote
and receiver was successful.
o
Note: sometimes the connection can take more than 10
seconds!!
o
It’s necessary that a reference movement is now performed. Now
keep the connecting button
A
pressed. Both motors of the bed are
moving to their Zero Position. When the white LED light on the
motor flashes 2 x, the reference movement was successful.
o
The adjustable bed is now ready to be used.
•
Manual connecting mode:
o
After the 60 seconds mentioned above the receiver leaves its
automatic connecting mode; the white LED lights go out and a
manual connecting mode has to be activated.
o
On the motor, press
2 x
the connecting button
A
until the white LED
lights will light up.
o
You now enter the manual connecting mode.
o
Press the remote buttons
1
&
2
(first row) TOGETHER.
o
The white LED on the motor flashes 2 x and goes out. The
connection between remote and receiver was successful.
o
Note: sometimes the connection can take more than 10
seconds!!
o
It’s necessary that a reference movement is now performed. Now
keep the connecting button
A
pressed. Both motors of the bed are
moving to their Zero Position. When the white LED light on the motor
flashes 2 x, the reference movement was successful.
Содержание 210820
Страница 2: ...90 OK 1 3 2 ...
Страница 5: ...4 5 C F P X C F ...
Страница 6: ...6 7 ...
Страница 7: ...or of ou oder 8 O X ...
Страница 11: ...12 B 1 2 3 ...
Страница 20: ...www instructions id g05if3w ...