10
Shutter motor
230 V / 50 Hz
Power grid
230 V / 50 Hz
1) white = Control line downward or upward
2) black = Pole contact rocker switch
3) brown = L1 / Phase
4) blue = N Neutral conductor
5) green/yellow = PE Protective conductor
1) brown / black = L1 / Phase
2) blue = N Neutral conductor
3) green/yellow = PE Protective conductor
1 (L1)
2 (N)
3 (PE)
2
3 (L1)
4 (N)
5 (PE)
•
On the opposite side of the motor, push the roller capsule out of the roller shutter shaft until it fits into the ball bearing inserted in the wall bearing.
•
Fix roller capsule to roller shutter shaft with self-tapping screw. Position the screw at a punched hole. This prevents the screw from slipping.
7
Shutter motor wiring:
•
Connect the radio shutter motor to the mains and, if necessary, connect the rocker switch to the motor cable.
•
The electrical connection of the roller shutter motor and control unit may only be carried out by qualified personnel.
1
8
Programming radio transmitter:
•
Pair the radio handheld transmitter to the shutter motor. See Programming radio transmitter (page 15).
•
If the direction of rotation is reversed, please change it with the paired radio handheld transmitter.
>
Changing the direction of rotation of the radio motor (Page 15).
Wire end caps
•
Use the enclosed wire end caps to insulate free wire ends of the
motor cable. If no rocker switch is connected the black and white
wires are unused and must be insulated. To do this, slide the wire
end caps onto the wire ends and press them together with crimping
pliers or combination pliers.
9
Setting the end positions:
•
The end points are set by radio handheld transmitter.
•
See programming end positions (page 16).
Rocker switch
3T-MOTORS Radio tubular motors
| Installation instructions
INSTALLATION INSTRUCTIONS
Roller capsule
Wall b
Ball bearing