Assembly instructions 

3P Volume Filter VF12 - installation 

 

 

 

Wastewater outlet: 

Base of drain pipe = shaft bottom 

12” 

 

Outlet to the cistern: 

Base of outlet pipe = 8.26” 

10” 

from shaft bottom 

 

2 x rainwater inlet: 

Base of inlet = 31.89” 

12” 

from shaft bottom 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

It is advisable to remove the lamella unit before assembly. 
To do this, undo the locking screws by 2 to 3 turns 

 

do not unscrew completely! 

Pull the lamella unit out upwards at an angle. 

 

When installing the shaft in the earth, protect the filter with a foil in order to avoid 
contamination of the filter with mortar when grouting the cone or the shaft rings. 

 

Содержание VF12

Страница 1: ...o 1000950 Rainwater filter conforming to DIN 1986 for roof areas up to 42 334 ft with a rain intensity of 4 hour Filter for installation into a pilot shaft Ø 78 or Ø 98 The lamella units with fine filter can be removed easily for cleaning Material Stainless steel ...

Страница 2: ...s Technical data 02 03 Method of functioning and areas of use 04 Assembly instructions installation 05 Installation instructions 06 Optimuminstallation position cleaning the filter removal of the lamella unit 07 Maintenance instructions and warranty 08 Technicaldata Rainwater filter for installation into a pilot shaft Side view Top view 2 ...

Страница 3: ...nical data 3PVolume FilterVF12 Rainwater supply Inlet to sewer Inlet to the cistern A B C D E F G 1 x 12 1 x 12 1 x 12 30 7 42 1 30 7 47 2 23 6 10 8 34 6 Screen mesh size in mm min shaft Ø 0 390 0 980 78 3 ...

Страница 4: ...t is directed straight to the seweragesystemviathecascades wastewater into the sewer 5 3 4 cleaned water into the cistern 3 Pre cleaned water is guided to the sieving area mesh width 0 390 x 0 980 mm Thanks to the special web structure of the screen dirt is fed into sewer hence the maintenance requirement is low 4 Cleaned water flows into the cistern 5 Dirt is washed into the sewer Areas of use 3P...

Страница 5: ... when assembling on the building site If connecting directly on the building site please ensure that the seals are seated cleanly The pipe sections should not project any further than 3 14 into the filter For the sealing of the drill holes in the shaft we recommend Forsheda seals The filter itself should be vertically levelled Compensation rods are included with which small differences can be comp...

Страница 6: ...et Base of inlet 31 89 12 from shaft bottom It is advisable to remove the lamella unit before assembly To do this undo the locking screws by 2 to 3 turns do not unscrew completely Pull the lamella unit out upwards at an angle When installing the shaft in the earth protect the filter with a foil in order to avoid contamination of the filter with mortar when grouting the cone or the shaft rings 6 ...

Страница 7: ...of a bypass High security due to bypass installation hence larger roof areas can also be connected Rainwater inlet Outlet into the sewer Cistern overflow Rainwater supply Cleaning the filter Outlet into the cistern CheckthefunctionofthevolumefilterVF12regularlyandcleanitasrequired Removalofthelamellaunit 7 ...

Страница 8: ...m that is free of defects If the repair fails twice or if it is not economically justifiable then the buyer client has the right to withdraw from the contract or to reduce its payment ob ligation accordingly Obvious defects must be reported immediately unrecognisable or concealed defects immediately upon their discovery in both cases in writing 3P Technik is liable for repairs and deliveries of ne...

Отзывы: