background image

 

 

1. 

Power supply indicator (P1-P2) 

2. 

Alarm indicator (ALM) 

3. 

Running indicator (RUN) 

4. 

Relay alarm output interface 

5. 

Grounding screw 

6. 

CONSOLE port 

7. 

Lugs 

8. 

Power input interface (P1-P2) 

9. 

Ethernet port indicator (E1-E8, G1-G4) 

10. 

Gigabit Bypass M12 interface (Two groups of 
Bypass: G1-G2 and G3-G4, or G9-G10 and G11-
G12) 

11. 

100M PoE indicator (E1-E8) 

12. 

100M PoE M12 interface (E1-E8) 

13. 

Gigabit PoE indicator (G1-G8) 

14. 

Gigabit PoE M12 interface (G1-G8) 

Mounting Dimension

 

Unit: mm

 

 

Notice Before Mounting: 

 

Don't place or install the device in area near water or 
moist, keep the relative humidity of the device 
surrounding between 5%~95% without condensation. 

 

Before power on, first confirm the supported power 
supply specification to avoid over-voltage damaging the 
device. 

 

The device surface temperature is high after running; 
please don't directly contact to avoid scalding. 

Wall-mounted Device Mounting

 

 

On the wall of device mounting, place the device on 
the wall for reference or refer to the mounting 
dimension to mark two screw positions. 

 

Hang the device on the labeled wall, align the bolt 
to the labeled position, then fix them with a certain 
gap. 

 

Slide the device down to hang on the screw, then 
tighten the screw, and the installation is finished. 

 

Wall-mounted Device Disassembling

 

 

Power off the device. 

 

Hold the device steadily and screw out the bolt in 
the wall. 

 

Take out the device, disassembling ends. 

Notice before power on: 

 

Power ON operation: First insert the power supply 
terminal block into the device power supply interface, 
then plug the power supply plug contact and power on. 

 

Power OFF operation: First, remove the power plug, then 
remove the wiring section of terminal block. Please pay 
attention to the above operation sequence.

 

Power Supply Connection

 

 

Model I and Model III: 24VDC power supply 

Supply supports non-polarity and redundant power 
input.The power supply interface adopts M12 A-
Coded 4-Pin pin (male) connector. The pin 
definitions are shown in the left figure. Power supply 

input range:   

-

 

Model I: 24VDC (18~36VDC). 

-

 

Model III: 24VDC (9~36VDC). 

 

model II, Model IV, Model V, Model VI:    110VDC 
power supply 

Supply supports non-polarity and redundant power 
input. The power supply interface adopts M12 A-
Coded 4-Pin pin (male) connector. The pin 
definitions are shown in the left figure. Power 

supply input range: 110VDC (66~156VDC). 

Relay Connection

 

This series device provides 1 M12 D-Coded 4-Pin 
slot (female) that supports 1 relay alarm output. R1 
and R2 are a set of normally open contacts of the 

device alarm relay. They are open circuit in the state of normal 
non alarm, closed when any alarm information occurs. For 
example: the relay supports the output of network abnormality 
alarm. It can be connected to alarm light or alarm buzzer or 
other switching value collecting devices, which can timely 
inform operators when the alarm occurs. The pin definitions of 
relay are shown in the figure. 

Console Port Connection

 

The series of device provides 1 program debugging 
port based on RS232 serial port which can conduct 
device CLI command management after 

connecting to PC. The interface adopts M12 D-Coded 4-Pin 
slot (female). The pin definitions of M12 are shown in the figure: 

Communication Interface Connection

 

 

100M PoE M12 interface 