Step 1
Check if the DIN-Rail mounting kit is installed firmly.
Step 2
Insert the bottom of DIN-Rail mounting kit (one side
with spring support) into DIN-Rail, and then insert
the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Step 3
Check and confirm the product is firmly installed on
DIN-Rail, then mounting ends.
【
Disassembling DIN-Rail
】
Step 1
Device power off.
Step 2
After lift the device upward slightly, first shift out the
top of DIN-Rail mounting kit, then shift out the
bottom of DIN-Rail, disassembling ends.
Note before powering on:
Power ON operation: first connect power line to the
connection terminal of device power supply, then power
on.
Power OFF operation: first unpin the power plug, then
remove the power line, please note the operation order
above.
【
Power Supply Connection
】
DC power supply
This device provides 3-pin industrial terminal blocks (1, 2, 3),
among which 1 and 3 are 12~48VDC power supply inputs.
This power supply supports non-polarity, it
could run normally when reversely
connected.
【
DIP Switch Setting
】
Provide 4-bits DIP switch for function setting,
where "ON" is enable valid terminal. The
definitions of DIP switch as follows:
No.
Definition
Operation
1
Flow control
Set the switch to ON
2
Specified 100M
Set the switch to ON
3
Remote alarm
Set the switch to ON
4
Jumbo frame mode
Set the switch to ON
【
Checking LED Indicator
】
The device provides LED indicators to monitor its operating
status, which has simplified the overall troubleshooting
process. The function of each LED is described in the table
below:
LED
Status
Description
RUN
ON
/
OFF
Device is in an abnormal state
Blinking
Device runs normally
PWR
ON
Power supply is connected and
running normally
OFF
Power supply is disconnected or
running abnormally
LINK(G1)
ON
Local copper port is connected
properly
Blinking
Local copper port is in an active
network state
OFF
Local copper port is not
connected
LINK(G2)
ON
Local fiber port is connected
properly
Blinking
Local fiber port is in an active
network state
OFF
Local fiber port is not connected
LFP(G1)
ON
Remote copper port is not
connected or connected
abnormally
OFF
Remote copper port is connected
properly
LFP(G2)
ON
Remote fiber port is not
connected or connected
abnormally
OFF
Remote fiber port is connected
properly
【
Specification
】
Panel
Gigabit SFP
1000Base-X, SFP slot
Gigabit copper port
10/100/1000Base-T(X)
self-adaption, RJ45 port,
self-adaptive full/half duplex
mode or specified operating
mode, supports MDI/MDI-X
self-adaption
Gigabit fiber port
1000Base-X, optional
SC/ST/FC
Indicator
Power supply indicator,
running indicator, port
indicator, LFP indicator
Switch property
Backplane bandwidth
12G
Buffer size
1Mbit
MAC address
1K
Power supply
Input power supply
DC power supply product
12
~
48VDC
Support non-polarity and
anti-reverse connection
Terminal blocks
3-pin 7.62mm pitch terminal
blocks
Power consumption