background image

 

Step 1 

Check if the DIN-Rail mounting kit is installed firmly. 

Step 2 

Insert the bottom of DIN-Rail mounting kit (one side 
with spring support) into DIN-Rail, and then insert 

the top into DIN-Rail. 

Tips: 
Insert a little to the bottom, lift upward and then insert 
to the top. 

Step 3 

Check and confirm the product is firmly installed on 

DIN-Rail, then mounting ends. 

Disassembling DIN-Rail

 

Step 1 

Device power off. 

Step 2 

After lift the device upward slightly, first shift out the 
top of DIN-Rail mounting kit, then shift out the 
bottom of DIN-Rail, disassembling ends. 

  Note before powering on:

 

 

Power ON operation: first connect power line to the 
connection terminal of device power supply, then power 
on. 

 

Power OFF operation: first unpin the power plug, then 
remove the power line, please note the operation order 
above.   

Power Supply Connection

 

 

DC power supply 

This device provides 3-pin industrial terminal blocks (1, 2, 3), 
among which 1 and 3 are 12~48VDC power supply inputs. 

This power supply supports  non-polarity, it 
could run normally when reversely 
connected. 

DIP Switch Setting

 

Provide 4-bits DIP switch for function setting, 
where "ON" is enable valid terminal. The 
definitions of DIP switch as follows: 

No. 

Definition 

Operation 

Flow control 

Set the switch to ON   

Specified 100M 

Set the switch to ON 

Remote alarm 

Set the switch to ON 

Jumbo frame mode 

Set the switch to ON 

Checking LED Indicator

 

The device provides LED indicators to monitor its operating 
status, which has simplified the overall troubleshooting 
process. The function of each LED is described in the table 
below: 

LED 

Status 

Description 

RUN 

ON 

OFF 

Device is in an abnormal state 

Blinking 

Device runs normally 

PWR 

ON 

Power supply is connected and 
running normally 

OFF 

Power supply  is disconnected or 
running abnormally 

LINK(G1) 

ON 

Local copper port is connected 
properly 

Blinking 

Local copper port is in an active 
network state 

OFF 

Local copper port  is not 
connected 

LINK(G2) 

ON 

Local  fiber  port is connected 
properly 

Blinking 

Local  fiber  port is in an active 
network state 

OFF 

Local fiber port is not connected 

LFP(G1) 

ON 

Remote copper port is not 
connected or connected 
abnormally 

OFF 

Remote copper port is connected 
properly 

LFP(G2) 

ON 

Remote  fiber  port is not 
connected or connected 
abnormally 

OFF 

Remote  fiber  port is connected 
properly 

Specification

 

Panel 

 

Gigabit SFP 

1000Base-X, SFP slot 

Gigabit copper port

 

10/100/1000Base-T(X) 
self-adaption,  RJ45  port, 
self-adaptive full/half duplex 
mode or specified  operating 
mode, supports  MDI/MDI-X 
self-adaption 

Gigabit fiber port 

1000Base-X, optional 
SC/ST/FC 

Indicator 

Power supply indicator, 
running indicator, port 
indicator, LFP indicator 

Switch property

 

 

Backplane bandwidth

 

12G

 

Buffer size   

1Mbit

 

MAC address 

1K

 

Power supply 

 

Input power supply 

 

DC power supply product 
12

48VDC 

Support non-polarity and 
anti-reverse connection 

Terminal blocks 

3-pin  7.62mm  pitch terminal 
blocks 

Power consumption 

 

Отзывы: