Note

10Base-T/100Base-TX, “TX

”transmit data

, “RX

”receive data

”not use. 

10/100Base-T(X) MDI (straight-through cable) 

 

10/100Base-T(X) MDI-X (Cross over cable) 

 

Gigabit MDI (straight-through cable) 

 

Gigabit MDI-X (Cross over cable) 

 

MDI/MDI-X  auto  connection  makes  switch  easy  to  use  for 

customers without considering the type of network cable.

 

1000Base SFP fiber port 

1000BaseSFP  optical  fiber  interface  is  used  SFP  optical  module 

communication  through  optical  fiber  transmission,  can  choice 

different  SFP  module  according  to  different  transfer  distance. 

Fiber  interface  must  use  for  pair,  TX  port  is  transmit  side,  must 

connect to RX (receive side). The fiber interface support loss line 

indicator. 

Suppose

:  If  you  make  your  own  cable,  we  suggest  labeling  the 

two  sides  of  the  same  line  with  the  same  letter  (A-to-A  and 

B-to-B, shown as below, or A1-to-A2 and B1-to-B2). 

     

 

LED Indicator

 

LED  indictor  light  on  the  front  panel  of  product,  the  function  of 

each LED is described in the table as below. 

System Indication LED 

LED 

State   

Description 

PWR 

(P1~P2) 

ON 

Power is being supplied to 

power input PWR input 

OFF 

Power is 

not

 being supplied 

to power input PWR input 

RUN 

ON/OFF 

System is not running well 

Blinking 

System is running well 

Alarm 

ON 

When the alarm is enabled, 

power or the port’s link is 

inactive. 

OFF 

Power and the port’s link is 

active, the alarm is disabled. 

Link/ACT 

(1~28) 

ON 

Port connection is active 

Blinking 

Data transmitted 

OFF 

Port connection is not active 

Installation

 

Before  installation,  confirm  that  the  work  environment  meet  the 

installation  require,  including  the  power  needs  and  abundant 

space. Whether it is close to the connection equipment and other 

equipments are prepared or not.   

1. Avoid in the sunshine, keep away from the heat fountainhead or 

the area where in intense EMI. 

2. Examine the cables and plugs that installation requirements. 

3. Examine whether the cables be seemly or not (less than 100m) 

according to reasonable scheme.   

4. Power: 100-240VAC power input 

5. Environment: working temperature: -40

70

 

Storage Temperature: -40

85

 

Relative humidity 5%

95% 

Rack mount installation 

In  most  of  industrial  application,  it  is  convenience  to  use  rack 

mount installation, the step of installation is as follows: 

1.

 

Check  if  have  rack  mount  installation  tools  and  components 

(The package provided parts of components) 

2.

 

Check installation place strong or not, have the place to install 

the device or not. 

3.

 

Put the device into rack, aim  at the screw hole of device and 

rack,  fixed  it  in  strong  screw.  Easy  and  convenience  to 

operation. 

Wiring Requirements 

Cable laying need to meet the following requirements,

 

1.

 

It  is  needed  to  check  whether  the  type,  quantity  and 

specification  of  cable  match  the  requirement  before  cable 

laying; 

2.

 

It  is  needed  to  check  the  cable  is  damaged  or  not,  factory 

records and quality assurance booklet before cable laying; 

3.

 

The  required  cable  specification,  quantity,  direction  and 

laying position need to match construction requirements, and 

cable length depends on actual position; 

Содержание IES5028G-8GC-4GS

Страница 1: ...ements and provide reliable and economic solutions for Ethernet access Packing list The industrial Ethernet switch is shipped with the following items If any of these items are missing or damaged please contact your customer service representative for assistance Industrial Ethernet switch 1 Documentation and software CD 1 User manual 1 Rackmount ears 2 Power cords 2 Features Support IGMP Snooping ...

Страница 2: ...ess terminals in the rear panel of the device next to the power input parts R and R are in the middle of the relay alarm output section It is used to detect both power failure and port failure The open circuit state in normal non alarm state when there is any alarm information to the closed state This series of switch device have 2 relay alarm output external alarm lights or alarm buzzer or extern...

Страница 3: ...ng Data transmitted OFF Port connection is not active Installation Before installation confirm that the work environment meet the installation require including the power needs and abundant space Whether it is close to the connection equipment and other equipments are prepared or not 1 Avoid in the sunshine keep away from the heat fountainhead or the area where in intense EMI 2 Examine the cables ...

Страница 4: ...rt 10 100 1000BaseT X flow control full half duplex adaptive work mode MDI MDI X adaptive Combo port 1000Base X SFP slot or 10 100 1000Base T X Gigabit SFP port 1000Base X SFP slot Console port CONSOLE Admin Port RJ45 Alarm port 5 core 5 08mm wiring terminal R R 2 way relay alarm output Transmission distance Twisted pair 100m standard CAT5 CAT5e cable Multi mode fiber 1310nm 2km Single mode fiber ...

Отзывы: