![3onedata IES3016 Series Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/3onedata/ies3016-series/ies3016-series_user-manual_444437002.webp)
IES3016-4F IES3016-6F
IES3016-8F
1. DIP switches (Retain)
2. Console port (Retain)
3. 2-pin terminal block for relay output (Retain)
4. Ground screw
5. Power input terminal block
6. DIN-Rail mounting kit
7. System running LED
8. Power indicator
9. Relay alarm LED
10. Link/ACT LEDs
11. 10Base-T /100Base-TX Ethernet port
12. 100Base-FX fiber port
【
Appearance and dimension
】
The series of products are the same size, and the number of the
Ethernet interface is different. Unit (mm)
【
Power supply input
】
DC Series Switch:
The product top panel provided 4 bit power supply input terminal
block, support DC input. DC power supply input supported
redundancy function, provided PWR1 and PWR2 power input,
can use for single, and can connect 2 separately power supply
system, use 1 pair terminal block connect the device at the same
time. If one of the power systems broke, the device can work
un-interruptible.
Built-in overcorrect protection,
Reverse
connection protection. Voltage input range is 12
~
48VDC
(
terminal block defined as: V1-
、
V1+
、
V2-
、
V2+
)
.
AC Series Switch:
The Industrial Ethernet switches have singe power and
redundancy power two kinds of power input. The singe power AC
series top panel provides 3 bit terminal block for AC100~240V
power entered (L/+, PG, N/-)
Important notice:
1.
Power ON operation: first of all, insert power cable’s terminal
block into device’s power port, then insert power supply plug into
power source
2.
Power OFF operation: First off all, unpin power plug, then
strike the terminal block, please take care of operation sequence.
【
Communication connector
】
10/100BaseT(X) Ethernet port
The pinout of RJ45 port display as below, connect by UTP or STP.
The connect distance is no more than 100m. 100Mbps is used
120
Ω of UTP 5; 10Mbps is used 120Ω of UTP 3, 4, 5.
RJ 45 port support automatic MDI/MDI-X operation. Can
connect the PC, Server, Converter and HUB .Pin 1,2,3,6
Corresponding connections
in MDI. 1→3, 2→6, 3→1, 6→2 are
used as cross wiring in the MDI-X port of Converter and HUB.
10Base-T/100Base-TX are used in MDI/MDI-X, the define of Pin
in the table as below.
1
8