DIP Switch  Definition  Operation 

Storm 
Suppression 

Set the switch to ON to enable 
storm suppression function 

VLAN 

Set the DIP switch to ON, Port 
1 is uplink port, Port 2-5 are the 
downlink ports, and the 
downlink ports are isolated 
from each other. 

Flow 
Control 

Set the switch to ON to enable 
flow control function 

 

Model II 

DIP 
Switch 

Definition  Operation 

Loop 
Detection 

Set the switch to ON to enable port 
loop detection function. When the 
loop is detected, the communication 
of one port will be blocked to avoid 
the storm, and the indicator of the 
loop port will flash to warn. 

Storm 
Suppression 

Set the switch to ON to enable storm 
suppression function 

VLAN 

Set the DIP switch to ON, Port 1 is 
uplink port, Port 2-8 are the downlink 
ports, and the downlink ports are 
isolated from each other. 

Flow 
Control 

Set the switch to ON to enable flow 
control function 

 

Model III 

DIP 
Switch 

Definition  Operation 

Flow control 

Set the switch to ON to enable flow 
control function 

Storm 
Suppression 

Set the switch to ON to enable storm 
suppression function 

3-4 

NC 

Reserved 

Notice:

 

The functions corresponding to the 4 DIP switches 
cannot be used at the same time. You can select one of 
them to set the function. 

Checking LED Indicator

 

Provide LED indicators to monitor its operating status, which 
has simplified the overall troubleshooting process. The 
function of each LED is described in the table below: 

LED 

Indicate  Description 

P1-P2 

ON 

Power supply is running normally 

OFF 

Power supply is disconnected or 
running abnormally 

RUN 

ON 

The device is powering on or  the 
device is abnormal. 

Blinking  The device is running normally 

OFF 

The device is powered off or the 
device is abnormal. 

1-5/8/16 

ON 

Ethernet port has established a valid 
network connection 

Blinking 

Ethernet port  is in an active 
network status 

Note: 
If loop detection is enabled and the port 
is looped, the loop port indicator would 
flash at a frequency of 1Hz for warning. 

OFF 

Ethernet port has not established a 
valid network connection. 

Specification

 

Panel 

 

100M copper port

 

10/100Base-T(X)  self-adaptive 
RJ45, full/half duplex mode 
self-adaption, MDI/MDI-X 
autotunning

 

Indicator 

Power indicator, running 
indicator, interface indicator 

Switch Property

 

 

Model I 

MAC address table: 2K 
Backplane bandwidth: 1G 

Model II 

MAC address table: 2K 
Backplane bandwidth: 1.6G 

Model III 

MAC address table: 8K 
Backplane bandwidth: 3.2G 

Power Supply

 

 

Input power supply

 

12/24/48 VDC(9~60VDC), dual 
power supply redundancy, 
support anti-reverse connection

 

Access terminal block 

4-pin 5.08mm pitch terminal 
blocks

 

Power Consumption 

 

Model I 

No-load: 0.2W@12VDC 
Full-load: 0.8W@12VDC 

Model II 

No-load: 0.4W@12VDC 
Full-load: 3.0W@12VDC 

Model III 

No-load: 0.7W@48VDC 
Full-load: 2.9W@48VDC 

Working Environment 

 

Working temperature

 

-40~75

 

Storage temperature 

-40~85

 

Working humidity

 

5%

95% (no condensation) 

Protection grade 

IP40 (metal shell) 

 