3onedata IES2100SL Series Скачать руководство пользователя страница 2

9. 

10/100Base-T(X) 100M copper port (1-5/8/16) 

Mounting Dimension

 

Unit: mm 

 

Model I 

 

 

Model II 

 

 

Model III 

 

Notice Before Mounting:

 

 

Don't place or install the device in area near water or 
moist, keep the relative humidity of the device 
surrounding between 5%~95% without condensation. 

 

Before power on, first confirm the supported power 
supply specification to avoid over-voltage damaging the 
device. 

 

The device surface temperature is high after running; 
please don't directly contact to avoid scalding. 

DIN-Rail Mounting

 

The product adopts 35mm standard DIN-Rail mounting which 
is suitable for most industrial scenes, mounting steps as 
follows: 

 

 

Check if the DIN-Rail mounting kit is installed firmly. 

 

Insert the bottom of DIN-Rail mounting kit (one side 
with spring support) into DIN-Rail, and then insert 
the top into DIN-Rail. 

Tips: 
Insert a little to the bottom, lift upward and then insert 
to the top. 

 

Check and confirm the product is firmly installed on 
DIN-Rail, then mounting ends. 

Disassembling DIN-Rail

 

 

Power off the device. 

 

After lifting the device upward slightly, first shift out 
the top of DIN-Rail mounting kit, and then shift out 

the bottom of DIN-Rail, disassembling ends. 

Notice before power on:

 

 

Power ON operation: First insert the power supply 
terminal block into the device power supply interface, 
then plug the power supply plug contact and power on. 

 

Power OFF operation: First, remove the power plug, 
then remove the wiring section of terminal block. Please 
pay attention to the above operation sequence. 

Power Supply Connection

 

Provide 2 power inputs, and adopt 
4-pin 5.08mm pitch terminal blocks. 
The power input supports 1 power 
supply alone or 2 power supply at 
the same time; When two power 
supplies  input at the same time, it 

supports redundant backup of power supply. If one power 
supply fails, the device can still work normally without 
interruption. Power supply supports anti-reverse connection, 
which cannot power the device but won’t damage it when it's 
reversely connected. The definitions of power pin are shown 
in the figure above, and the power input range is 12/24/48 
VDC (49~60VDC). 

DIP Switch Settings

 

Provide 4 pins DIP switch for function settings, where "ON" is 
enable valid terminal. The definitions of DIP switch are as 
follows: 

 

Model I 

DIP Switch  Definition  Operation 

Loop 
Detection 

Set the switch to ON to enable 
port loop detection function. 
When the loop is detected, the 
communication of one port will 
be blocked to avoid the storm, 
and the indicator of the loop 
port will flash to warn. 

Отзывы: