3onedata ICS6420 Series Скачать руководство пользователя страница 2

 

The device surface temperature is high after running; 
please don't directly contact to avoid scalding. 

DIN-Rail Mounting

 

The product adopts 35mm standard DIN-Rail mounting which 
is suitable for most industrial scenes, mounting steps  as 
follows: 

 

Step 1 

Check if the DIN-Rail mounting kit is installed firmly. 

Step 2 

Clip the upper part of the DIN-Rail mounting kit, i.e. 
the fixed side, into the DIN rail. 

Step 3 

Press the lower side of the device and insert the 
lower part of DIN-Rail mounting kit (the side  with 
spring support) into DIN-Rail. 

Tips: 
The DIN-Rail spring support is a metal sheet that can 
move up and down, and there will be a sound after it is 
clamped in. 

Step 4 

Check and confirm the product is firmly installed on 
DIN rail, then mounting ends. 

Disassembling DIN-Rail

 

 

Step 1 

Power off the device. 

Step 2 

Use a slot type screwdriver or other tools to move 
the DIN rail spring support downward; At the same 
time, move the lower side of the device outward 
and move out the lower part of the DIN rail 
mounting kit. 

Step 3 

Lift the device upward slightly, move out the upper 
part of DIN-Rail mounting kit. Disassembling ends. 

Notice before powering on:

 

 

Power ON operation: First insert the power supply 
terminal block into the device power supply interface, 
and then plug the power supply plug contact and power 
on. 

 

Power OFF operation: First, remove the power plug, 
then remove the wiring section of terminal block. Please 
pay attention to the above operation sequence. 

Power Supply Connection

 

This series device provides 6-pin 5.08mm 
pitch input terminal blocks, including 4 
pins power supply terminal blocks on the 
left side. It provides two independent DC 

power supply systems of P1 and P2. The power supply is 
anti-reverse connection. 
Voltage range: 12~48VDC. 

Relay Connection

 

This series device provides 6-pin 5.08mm 
pitch input terminal blocks, and the relay 
occupies the right 2 pins. Relay terminals 
are a set of normally open contacts of the 

device alarm relay. They are open circuit in the state of normal 
non alarm, closed when any  alarm information occurs. For 
example, they are closed when powered off, and send out 
alarm. The product supports 1 relay alarm information output 
that can output DC power supply alarm information or network 
abnormality alarm. It can be connected to alarm light or alarm 
buzzer or other switching value collecting devices, which can 
timely inform operators when the alarm occurs.

 

DIP Switch Settings

 

This series provides 4-pin DIP switch for function 
setting, in which “ON” is the enabled end. The 
definitions of DIP switch are as follows: 

PIN 

2-4 

Definition 

Reboot: set the switch to ON, 
then set it to OFF after 1-2 
seconds, the system will reboot 
automatically. 
Restore factory settings: set the 
switch to ON, then set it to OFF 
after 5 seconds, the system will 
automatically restore the factory 
settings. 

Reserved 

Console Port Connection

 

This series  provides 1 program debugging port based on 
RS-232 serial port which can conduct device CLI command 
management after connecting to PC. The interface adopts 
RJ45 port, the RJ45 pin definition as follows: 

Pin No. 

Definition 

TXD 

RXD 

GND 

Checking LED Indicator

 

This series  provides LED indicators to monitor its operating 
status, which has simplified the overall troubleshooting 
process. The function of each LED is described in the table 
below: 

LED 

Indicate  Description 

P1-P2 

ON 

Power is connected and running 
normally 

OFF 

Power supply is disconnected or 
running abnormally 

ALM 

ON 

Power supply or port link has alarm 

OFF 

Power supply and port link have no 
alarm 

RUN 

ON 

The device is powering on or the 
device is abnormal. 

OFF 

The device is powered off or the 

Отзывы: