3. Press SET again to enter IR sensitivity adjustment.

4. Press SET again to enter Size sensitivity adjustment.

5. Press SET again to enter Voice ON and OFF (some models might differ).

Increased
sensitivity

Decreased
sensitivity

Increased
sensitivity

Decreased
sensitivity

Turn Off

Turn On

Содержание BC1005

Страница 1: ......

Страница 2: ...plug is well connected to mainboard 2 If it is well connected please change the mainboard with normal mainboard 3 If normal mainboard has been changed but still not working then change left counting s...

Страница 3: ...king please change the mainboard ALARM CODES E17 1 Suspicious fake notes detection by UV method 2 Real banknote which had been washed might also caused E 17 3 If note is real UV sensor might be damage...

Страница 4: ...n the machine listen the big motor sound if it is not working a Big motor plug not connected well to mainboard b Main board damaged c Capacitor is damaged 3 If big motor is working check the feeding r...

Страница 5: ...show software version SETTING MENU Hold press SET 5 6 second to enter the SET program 1 MG sensitivity adjustment 2 Press SET again to enter UV sensitivity adjustment Increased sensitivity Decreased s...

Страница 6: ...adjustment 4 Press SET again to enter Size sensitivity adjustment 5 Press SET again to enter Voice ON and OFF some models might differ Increased sensitivity Decreased sensitivity Increased sensitivit...

Страница 7: ...differ 7 Press SET again to set the alarmed note to be counted or ignored 8 Press SET again to set batch mode to automatically count when number is reached and notes are taken from stacker or need to...

Страница 8: ...in to turn ON or OFF the detection of the following note after an alarmed note 10 Press SET again to set breaking time during batch or stop NOTE DO NOT NEED TO ADJUST Please contact factory in advance...