3nh NR60CP Скачать руководство пользователя страница 3

NR Series Precision Colorimeter 

 

   

Product Description 

 
This  instrument  is  researched  and  developed  in  accordance  with  CIE 
(International  Commission  on  Illumination)  and  CNS  (China  National 
Standards). It is a high precise colorimeter with simple user interface and 
stable performance. It can be powered by both Li-ion battery and external 
DC power supply. 
 
The instrument has following advantages: 
 
● Can perform measurement at start-up. No need to calibrate each time which 
simplify the operation. 
 
●  Adopt  illuminating  locating  and  precise  cross  locating  to  aim  at  the  tested 
object quickly. 
 
● 4mm measuring aperture for more measurement occasions. 
 
● Save data automatically. 
 
●  The  precise  and  stable  hand-head  structure  to  make  the  measurement 
easier. 
 

Cautions 

 

●  This  colorimeter  is  a  precise measuring  instrument. Please  avoid  dramatic 

changes  of  external  environment  when  measuring.  These  changes, 
including  the  flicker  of  surrounding  light,  the  rapid  change  of  temperature, 
will affect the measuring accuracy. 

 
● Keep the instrument balanceable; make sure the measuring aperture cling to 

the test sample, and no shaking or shifting when measuring. Please prevent 
the colorimeter from fierce collision or crash. 

 
● This instrument is not waterproof. Do not use it in high humidity environment 

or in water. 

 
● Keep the colorimeter clean. Avoid dust, powder or solid particles entering the 

measuring aperture and the instrument. 

 

Содержание NR60CP

Страница 1: ......

Страница 2: ...easurement Locating 9 2 Standard Measurement 9 3 Sample Measurement 10 III Connect Colorimeter to PC 11 IV Print 13 VI System Function Description 14 1 Record and Standard Entering 14 2 White and Blac...

Страница 3: ...ng aperture for more measurement occasions Save data automatically The precise and stable hand head structure to make the measurement easier Cautions This colorimeter is a precise measuring instrument...

Страница 4: ...cabinet when not in use Please take out the battery to prevent the colorimeter from damage if you don t use it for a long time Please keep the colorimeter in a cool dry place Any unauthorized changes...

Страница 5: ...olorimeter 3 I Button Description The following is a brief introduction of the buttons We will give more detailed information about its function separately in next chapters Figure 1 Button Function Up...

Страница 6: ...NR Series Precision Colorimeter 4 Figure 2 Testing Button Diagram Button Function Introduction 1 Menu 2 Up 3 Down 4 Enter 5 Back 6 Testing Testing...

Страница 7: ...s used to connect to external power source The speci cation of external power source is 5V 2A 3 USB Interface RS 232 Interface This interface is a common interface The instrument judges the connection...

Страница 8: ...external power source or USB cable to connect the PC Meanwhile push the switch to 1 and then the battery will be charging If not charge the battery then take out the battery and connect external power...

Страница 9: ...NR Series Precision Colorimeter 7 Figure 4 Battery Installation Li ion Battery Battery Cover...

Страница 10: ...th integrating sphere Then the installation is nished 2 Measuring Aperture Dismantlement As shown in Figure 5 gently turn measuring aperture clockwise When hear slight Da it means the measuring apertu...

Страница 11: ...rement or Sample Measurement interface press the Testing key and hold it The facula will appear at the moment You can observe the matching status between the facula and the measured sample At the same...

Страница 12: ...ment Interface 3 Sample Measurement After completing standard measurement press Enter button the instrument will enter Sample Measurement interface automatically as shown in Figure 7 Align the measuri...

Страница 13: ...nect Colorimeter to PC only for models equipped with software Press MENU button to enter the main menu as shown in Figure 8 Then select Comm to enter an interface shown in Figure 9 Follow the tips in...

Страница 14: ...NR Series Precision Colorimeter 12 Figure 8 Main Menu Figure 9 USB Communication...

Страница 15: ...Colorimeter 13 Figure 10 Communicating Interface IV print Connect colorimeter to the printer When the colorimeter is in Standard Measurement or Sample Measurement interface you can print measurement...

Страница 16: ...menu to enter Standard Record as shown in Figure 11 The gure shows the standard sample data You can check di erent standard data through Up and Down T002 is a standard number After selecting a standa...

Страница 17: ...standard record is entered to the measurement interface press Enter you can perform sample measurement under this standard c Sample Record Entered to a Standard In some cases it s needed to use a stor...

Страница 18: ...aperture upwards then put the white calibration board in the center of the colorimeter and make sure it is closed to measuring aperture Re press Testing key to perform white calibration Next step is...

Страница 19: ...owing occasions first use great change of the environment long term unused or inaccura te data 3 Tolerance Setting Select Tolerance in main menu to enter tolerance setting interface as shown in Figure...

Страница 20: ...nagement If E is smaller than tolerance value then it is quali ed If E is bigger than tolerance value then it is unquali ed As shown in Figure 14 1 the E in sample measurement interface is unquali ed...

Страница 21: ...les When select Delete All Samples it will delete all test samples in the instrument and save the standard records Then the instrument will display a warning interface as shown in Figure 16 Press Ente...

Страница 22: ...ords in the instrument will be deleted including all standard records and all sample records Then the instrument will pop up a warning interface as shown in Figure 17 Press Enter button all records in...

Страница 23: ...18 You can set the times of average measurements according to your need You can add or subtract the times by pressing Up and Down buttons Press Enter to save the settings and return to the main menu...

Страница 24: ...in menu to enter an interface as shown in Figure 19 You can select di erent color spaces according to your need This selection will a ect the display in Standard Measurement and Sample Measurement int...

Страница 25: ...Colorimeter 23 Figure 19 Display Mode Interface The display mode will default to CIE L a b C H Other options are CIE L a b CIE XYZ Measurement interfaces of each option are corresponding Figure 20 Fig...

Страница 26: ...NR Series Precision Colorimeter 24 Figure 20 CIE L a b C H Measurement Interface Figure 21 CIE L a b Measurement Interface...

Страница 27: ...ttings in main menu to enter an interface shown in Figure 23 You can select the object according to your need by pressing Up and Down buttons Press Enter to enter the corresponding setting interface A...

Страница 28: ...nction Settings Interface a Select Function Settings Language to enter an interface shown in Figure 24 You can select the language according to your need by pressing Up and Down buttons Press Enter to...

Страница 29: ...on Up and Down In Figure 26 and Figure 27 you can add or subtract time and date by pressing the button Up and Down In Figure 28 and Figure 29 you can set display format of time and date by pressing Up...

Страница 30: ...NR Series Precision Colorimeter 28 Figure 25 Time Date Setting Figure 26 Time Setting...

Страница 31: ...NR Series Precision Colorimeter 29 Figure 27 Date Setting Figure 28 Time Format...

Страница 32: ...ter an interface shown in Figure 30 Press Enter button The instrument will restore to factory default setting and clear all records Note When you choose this setting it will pop up a warning Please op...

Страница 33: ...NR Series Precision Colorimeter 31 Figure 30 Restore Factory Settings...

Страница 34: ...y and accurately Small measuring aperture easy to measure concave convex object No need to calibrate each time which simplify the operation New integrating sphere optical path design improve measureme...

Страница 35: ...face Detector Silicon photoelectric diode Color Space CIEL a b C h CIEL a b CIEXYZ Color Di erence Formula E ab L a b E C h Light Source D65 Measuring light source LED blue light excitation Errors bet...

Страница 36: ...y range relative humidity 0 85 with no condensation PC Software CQCS3 Color Quality Management Software Data interface USB RS232 Portable packing bag Original Standard accessories Powder adapter Li io...

Страница 37: ...have modulated the light source spectrum Di erent objects have di erent re ectance spectra transmittance spectra The light source spectrum modulates the re ectance spectra transmittance spectra of di...

Страница 38: ...the color di erence units calculated by other color di erence formulas are all NBS In national standards GB7705 87 lithograph GB7706 87 letterpress GB7707 87 gravure which promulgated by the National...