Figure 5:  NiMH Battery Pack

Power Options

There are 3 options for powering the WB-300: a 9-volt alkaline battery, a NiMH (Nickel Metal 

Hydride) rechargeable 6-cell battery pack, and an AC adapter.  A door on the back of the instru-

ment allows the user access to the 9-volt battery.  The rechargeable battery pack is located inside 

of the unit.  If the rechargeable battery pack ever needs to be replaced, it can be accessed by 

removing the screws from the bottom panel of the unit.
The 2-position switch located in the battery compartment must be set by the user if the power 

supply method is changed.  The up position is for the 9-volt battery.  The down position allows 

for either the AC adapter or the rechargeable batteries.  The AC adapter will trickle charge the 

rechargeable batteries if they are in place or it will simply allow for line power operation of the unit.

9-V Alkaline Battery Replacement  

The 9-volt battery should be replaced or the NiMH battery pack should be recharged when the 

voltage drops below 6.4 volts.  The battery voltage is displayed when the instrument is turned 

on.  While turned on, the battery voltage can be displayed at any time by pressing the up or 

down arrow keys to move through the display until the battery voltage screen appears.  If, while 

operating, the battery voltage drops below 6.4 volts, the display will automatically switch to 

the display showing the battery voltage along with a low battery message.  After a low battery 

occurs, the unit will continue to operate for approximately 8 hours.  When the battery voltage 

falls to 6.2 volts or below, the unit will automatically turn off. 

NiMH Battery Pack

 

The NiMH rechargeable battery pack is charged in the instrument using  120VAC to 9VDC 

adapter.  A discharged battery pack requires a charge of 16 hours.  Leaving the AC adapter 

plugged in for extended lengths of time or when operating the instrument will not harm the 

rechargeable batteries.

NiMH Battery Pack

To install, slide into case and plug in 

connector as shown.

Power Options 

6      Power Options

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание WIBGET WB-300

Страница 1: ...Occupational Health and Environmental Safety Division 3MTM WIBGETTM Heat Stress Monitor WB 300 WIBGET WB 300 User Manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 2: ...uracy of the instrument Repair should be completed by authorized service personnel only Caution General Replacement of 9 V alkaline battery only in a non hazardous locations If recharging with a NiHM Battery pack recharge only in a non hazardous environment A non condensing environment is required for proper measurements Do not charge battery outside the range of 0 C to 40 C 32 F to 104 F Battery ...

Страница 3: ...ta 6 Setup 7 Placing the WB 300 on site for monitoring testing 7 Operational Check 8 Power Options 8 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 10 10 11 12 12 12 Figures Figure 1 Wet bulb and maintenance 4 Figure 2 Keypad keys identified 5 Figure 3 Sensors identified 6 Figure 4 Data measurement screen examples 7 Figure 5 NiMH Battery Pack 9 ii Table of Contents www GlobalTestSupply com Find Quality Products On...

Страница 4: ...ral wet bulb The WB 300 uses a cotton wick immersed into a reservoir containing distilled water Ordinary tap water should not be used as the contaminants that are left behind after evaporation will shorten the life of the wick and cause high readings If the wick is discolored it should be replaced To replace the wick slide the old wick off the top of the sensor Place a new wick over the sensor mak...

Страница 5: ... hand corner of the display Enter setup changes While in Setup screen press to enter or select setup changes Setup The key allows changing the setup parameters Two parameters are available Celsius or Fahrenheit and language selection Setup Press setup to access the parameters Use the arrow keys to switch between the two parameters Press the enter key to change the parameters Press setup again to e...

Страница 6: ... on an individual due to either direct light or hot objects in the environment This is accomplished by placing a temperature sensor inside a blackened copper sphere and measuring the temperature rise The WBGT index is based on the response of a 6 inch diameter globe The WB 300 uses a 2 inch diameter globe for a faster response time The temperature of the 2 inch globe is correlated to match that of...

Страница 7: ...splay WBGT outdoor 0 7WB 0 2G 0 1DB denoted as WBGTo on the display NOTE The resulting WBGTi WBGTo can be compared to indices of work rest regimens or stay times based upon the work loads Please see Appendix B for published heat exposure tables Displayed Data When powered on the previously viewed measurement screen will be displayed To view data screens press the or keys Data Screens The following...

Страница 8: ...ed water and that the cotton wick is clean and fully wetted After adding water or placing the unit in a new environment allow ten minutes for the globe and wet bulb readings to stabilize A series of dashes appear in the display if one of the following occur The temperature is outside of its allowable range A temperature sensor has failed Operational Check A verification module 3M ID 70071581246 ma...

Страница 9: ...pack should be recharged when the voltage drops below 6 4 volts The battery voltage is displayed when the instrument is turned on While turned on the battery voltage can be displayed at any time by pressing the up or down arrow keys to move through the display until the battery voltage screen appears If while operating the battery voltage drops below 6 4 volts the display will automatically switch...

Страница 10: ...tween 32o F to 212o F Operating Temperature Range Sensor Assembly 5o C to 100o C 23o F to 212o F Electronics 5o C to 60o C 23o F to 140o F Power Options 9V alkaline 7 2V NiMH rechargeable pack charged in the unit or AC adapter wall power cube AC adapter will power the unit or recharge the NiMH battery pack Battery Life 9V alkaline 140 hours Rechargeable Nickel Metal Hydride 300 hours Charge Time N...

Страница 11: ... 25 5 25 to 50 32 0 30 0 29 0 28 0 0 to 25 32 5 31 5 30 5 30 0 Work and recovery Action Limit Light Moderate Heavy Very Heavy 75 to 100 28 0 25 0 22 5 20 0 50 to 75 28 5 26 0 24 0 22 5 25 to 50 29 5 27 0 25 5 24 5 0 to 25 30 0 29 0 28 0 27 0 Values not specified by ACGIH have been estimated for continuity Cited from American Conference of Governmental Industrial Hygienists Threshold Limit Values a...

Страница 12: ...2 55 2 15 1 30 93 0 4 25 3 50 3 15 2 40 2 00 1 25 94 0 4 05 3 35 3 00 2 25 1 50 1 15 95 0 3 45 3 15 2 45 2 15 1 45 1 10 96 0 3 25 3 00 2 30 2 05 1 35 1 05 97 0 3 10 2 45 2 20 1 55 1 25 1 00 98 0 2 55 2 35 2 10 1 45 1 20 0 55 99 0 2 40 2 20 2 00 1 40 1 15 0 50 100 0 2 30 2 10 1 50 1 30 1 10 0 45 101 0 2 20 2 00 1 40 1 25 1 05 0 45 102 0 2 10 1 50 1 35 1 15 1 00 0 40 103 0 2 00 1 45 1 25 1 10 0 55 0...

Страница 13: ...it is maintained and used in accordance with 3M instructions and or recommendations If any component becomes defective during the warranty period it will be replaced or repaired free of charge This warranty does not apply to units that have been altered or had repair attempted or that have been subjected to abuse accidental or otherwise The above warranty is in lieu of all other express warranties...

Страница 14: ... Printed in U S A 3M and WIBGET are trademarks of 3M Used under license in Canada 2011 3M Company All rights reserved 34 8706 7556 7 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Отзывы: