background image

 

 10

 

Carbon 
arc 
welding

 

 

 

 

 

 

 

 

 

 

 

14

 

 

 

 

Plate thickness, inches

 

< 1/8

 

 

 

 

 

 

 

 

4-5

 

 

1/8-1/2

 

 

 

 

 

 

 

 

5-6

 

 

Gas 
welding

 

 

> 1/2

 

 

 

 

 

 

 

 

6-8

 

 

< 1

 

 

 

 

 

 

 

 

3-4

 

 

1-6

 

 

 

 

 

 

 

 

4-5

 

 

Oxygen 
cutting

 

 

> 6

 

 

 

 

 

 

 

 

5-6

 

 

 

TROUBLESHOOTING

 

 

Condition Possible 

Solutions 

Make sure the batteries are installed properly 

Make sure the correct batteries are being used (CR2032) 

ADF will not turn ON 

Try replacing both batteries with new batteries, then checked the Low 
Battery indicator 

ADF shuts OFF and won’t 
turn back on 

Try replacing both batteries with new batteries, then checked the Low 
Battery indicator 

Check that the protective film has been removed from both sides (if 
applicable) of the outer protection plate 

Verify that the two sensors on the front of the ADF are not blocked by 
weld spatter, hands, pipes or object being welded 

Are you using the right 3M™ Speedglas™ ADF model? The 3M™ 
Speedglas™ Utility ADF is not recommended for welding processes other 
than MIG (GMAW) and Stick (SMAW). 

ADF does not trigger 
reliably or turns light 
intermittently while 
welding 

Review the sensitivity adjustment instructions and confirm that you are 
using the appropriate setting for your type of welding process 

ADF turns dark when 
others are welding nearby 

Reduce sensitivity.  If this is still occurring at setting 1, use curtains or 
other methods to block light from other welder's arcs. 

ADF steadily pulsing 
light/dark with no arc 
present. 

Check surrounding area for process or safety strobe lights.  Strobe lights 
can trigger ADFs from a long distance or by reflecting off ceilings.  
Reflected light from strobes not visible to the eye may be strong enough to 
trigger the ADF.  

ADF is “blurry” 

Check that the protective film has been removed from both sides (if 
applicable) of the outer protection plate 

ADF has spatter bonded to 
the outside and/or inside 
glass surface 

ADF is permanently damaged and not covered by warranty.  Always use 
outside and inside protection plates. 

  

Содержание Speedglas Utility

Страница 1: ...rm the inspection described in these User Instructions to ensure that all components are installed and functioning as intended Use of 3M welding helmet assemblies that do not meet these inspection req...

Страница 2: ...g filter plates 3M Speedglas 9000 Series Helmets feature patented aerodynamically designed vents to help exhaust exhaled air and reduce stuffiness inside the welding helmet The 3M Speedglas Utility He...

Страница 3: ...hield and Retainer Material Polyamide nylon ADF Housings Polyamide nylon REPLACEMENT PARTS AND ASSEMBLIES Replacement ADFs 04 0000 15 9002D ADF only 04 0000 shade 10 11 or 12 X 9000XF ADF only 04 0000...

Страница 4: ...Inner Shell 9000 Shield only 04 0014 00 3M Speedglas Utility Helmet with Headband 04 0114 00 3M Speedglas Utility Helmet Inner Shell 04 0212 00 3M Speedglas Silver Front Panel 04 0650 00 3M Speedglas...

Страница 5: ...overhead band to one of the custom fit positions for proper shield depth and to ensure balance and stability Figure 1 The headband also has a ratcheted knob to increase or decrease its circumference...

Страница 6: ...ally blocked arcs 9002D Low Normal sensitivity for typical SMAW MIG and TIG welding indoors and outdoors High High sensitivity for low current or stable arcs e g TIG welding at low amps Finding the ri...

Страница 7: ...should be replaced when the ADF does not turn noticeably lighter shade 5 to 3 when switched on In addition all 9002 models have a low battery indicator that will flash repeatedly when the battery sho...

Страница 8: ...four holes on the lens holder with the four tabs on the black side of the silver front panel Secure one corner at a time by pushing together the lens holder and silver panel so each tab snap locks Fi...

Страница 9: ...s not function as described above immediately contact your supervisor or 3M representative CLEANING AND STORAGE Clean the welding helmet with mild soap and lukewarm water Do not use solvents Clean the...

Страница 10: ...ed for welding processes other than MIG GMAW and Stick SMAW ADF does not trigger reliably or turns light intermittently while welding Review the sensitivity adjustment instructions and confirm that yo...

Страница 11: ...11...

Страница 12: ...ress warranty for a specific purpose 3M s only obligation and your exclusive remedy shall be at 3M s option to repair replace or refund the purchase price of such parts or products upon timely notific...

Страница 13: ...use or misuse of 3M OH ESD products or the user s inability to use such products THE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE 3M and Speedglas are trademarks of 3M FOR MORE INFORMATION In United State...

Отзывы: