Displayed Items
Run
12
Screen 2:
GLOBE
Figure 1-10: Globe screen
Screen 3:
WBGTi (Indoors)
WBGTo (Outdoors)
Figure 1-11: WBGTi & WBGTo screen
Screen 4:
RH (Relative Humidity)
H.I. or HU
(Heat Index or Humidex)
Figure 1-12: RH and H.I/HU screen
Screen 5:
Air Flow
(If turned ON via setup
with QUESTempº 36 only)
Figure 1-13: Air Flow screen
Screen 6:
Stay times
(QUESTempº 36 only)
Figure 1-14: Stay times (ACGIH)
Screen 7:
Time (24 hour format)
Date (day, month, year)
Figure 1-15: Time & Date screen
Screen 8:
BAT (Battery voltage)
MEM (Logging memory
available in days)
Figure 1-16: Battery & Memory screen
NOTE:
A series of dashes appear in the display if one of the following occur:
•
The Heat Index or Humidex is outside of its allowable range.
•
The temperature is outside of its allowable range.
•
A temperature sensor has failed.
•
Stay times temperatures are outside of the defined range.
GLOBE
92.4.
º
F
1
WBGT
i
84.1
º
F
1
WBGT
o
107.5
º
F
RH
66.2
%
1
H.I. 84.3
º
F
FLOW
0.3m/s
1
L M
H VH
1
60 45 30 15
TIME 11:04:13
1
DATE 26-JUN-08
BAT 11:04:13
1
MEM 10.4dy