3M PELTOR RCU-300 Скачать руководство пользователя страница 13

11

The SCU-300 will not 

connect with or operate 

the ComTac™ VII and/or 

TEP-300.

Make sure there are fully charged batteries in the SCU-300.
Restart the ComTac™ VII and/or TEP-300. For more information see product manuals for 

ComTac™ VII and/or TEP-300.
Restart the SCU-300. 

Make sure the SCU-300 is correctly fitted and aligned with ComTac™ VII. 

Refer to the manual 

for “3M™ PELTOR™ Tactical Modular Audio System”.
Make sure the products in the 3M™ PELTOR™ Tactical Modular Audio System have been 

started in the correct order. Refer to the manual for “3M™ PELTOR™ Tactical Modular Audio 

System”.
Press and hold the menu button on the SCU-300 for at least 10 seconds or until 2 short beeps 

indicates a successful pairing. The headset will indicate “NFMI pairing on”.
Do a factory reset of the SCU-300. Refer to “8.4.19. Factory reset”.

NFMI connection is 

unstable.

If several users are placed close to each other, connect your headset to SCU-300 with the 

headset cable. Refer to ““6.9. To connect to an external radio”.

I get thrown out of the 

menu.

The user automatically exits the menu if no button is pressed for 10 seconds.

I cannot control the system 

with the RCU-300.

Make sure there are fully charged batteries in the SCU-300.
Check the battery level of the RCU-300. Refer to “8.4.1. Battery status”.
Pair the SCU-300 to the RCU-300. Refer to “6.6. To pair the RCU-300 to the SCU-300”.
Make sure that you are using the correct RCU-300. 
Make sure the RCU-300 is not too far away from the SCU-300. 
Do a factory reset of the RCU-300. Refer to “6.4. To power on the RCU-300”.

EN

10.  STORAGE AND DISPOSAL

10.1.  STORAGE

•  Clean the product before storage.
•  Examine the product for wear or damage.
•  Keep the product in a clean and dry area within a 

temperature range of: -20°C/-4°F to 50°C /122°F.

•  Do not put the product in sunlight during storage.
•  During long term storage, remove the batteries from  

the battery holder. 

10.2.  DISPOSAL

•  Obey national regulations.
•  To properly dispose of the battery, follow local solid waste 

disposal regulations.

•  Use the local recycling system for electronic equipment. 
•  This product contains electrical and electronic components 

and must not be disposed of using standard refuse 

collection. Please consult local directives for disposal of 

electrical and electronic equipment.

Содержание PELTOR RCU-300

Страница 1: ...TM System Control Unit SCU 300 Remote Control Unit RCU 300 ...

Страница 2: ...3M PELTOR SCU 300 RCU 300 EN 1 12 ES 13 24 FR 25 36 ...

Страница 3: ...s subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesirable operation Note Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment Note This equipment has been tested and found to comply with th...

Страница 4: ...B E O P N M Q O button P PTT II button Q button SCU 300 A Intercom socket B Headset socket C Radio 1 socket D Radio 2 socket E PTT I button F PTT II button G button H button I On Off Menu button J Function button K Battery compartment cap L Metal clip 4 OVERVIEW EN ...

Страница 5: ...the scu 300 2 Press and hold the On Off Menu button on the SCU 300 for 3 seconds ON 3 sec 2 sec OFF 3 The TEP 300 and or the ComTac VII will indicate pairing 2 short beeps indicates a successful pairing to the SCU 300 3 long beeps indicates the NFMI link is lost Beep Beep Beeeep Beeeep Beeeep Note Beeping sounds only occur if the headset has previously been paired with the SCU 4 If pairing fails c...

Страница 6: ...ith SCU 300 There is no need to manually power off the RCU 300 6 6 TO PAIR THE RCU 300 TO THE SCU 300 RCU 300 uses Bluetooth Low Energy BLE communication BLE is a short range wireless communication protocol It is designed for long battery life The range is 50 cm 20 in Pairing the RCU 300 to the SCU 300 requires the use of the TEP 300 or ComTac VII headset Refer to those product user instructions f...

Страница 7: ...eat the steps to pair a second RCU 300 Note To reset the RCU 300 press and hold the and button on the RCU 300 for 10 seconds 6 7 TO FIT THE SCU 300 1 Slide the metal clip onto the rails on the back of the SCU 300 2 Attach the SCU 300 to your protective vest according to the illustration IMPORTANT Make sure that the SCU 300 is placed in upright position and as high as possible within the chest area...

Страница 8: ...he SCU 300 for the radio 5 Connect the cable with the SCU 300 and turn the cable clockwise to lock into place 6 10 TO CONNECT AN EXTERNAL INTERCOM 1 Connect the cable to the intercom system For instructions how to connect the intercom system refer to the intercom manual 2 Align the markings on the cable to the markings on the SCU IMPORTANT Make sure to select the correct socket on the SCU 300 for ...

Страница 9: ...et volume will not be available In that case it is necessary to enter the menu and select Ambient Listening Volume to change the volume of those devices 7 3 TO ADJUST THE RADIO INTERCOM VOLUME USING THE SCU 300 OR RCU 300 1 Short press both and buttons simultaneously 0 5 sec 2 Press either the or button to within 2 seconds to change the volume level on connected devices After 2 seconds the volume ...

Страница 10: ...ck beeps to indicate that the voice guided function is active and is waiting for your instructions 2 Say call followed by a name from your contact list or dial followed by a number 7 5 2 TO TRANSFER THE FUNCTION BUTTON TO THE RCU 300 To add the Function button capability to the RCU 300 change the settings on the SCU 300 1 Short press the power button on the SCU 300 to access the menu 0 5 sec 2 Pre...

Страница 11: ...e automatic audio messages Select between high or low based on the surrounding noise 8 4 4 NFMI PAIRING Pairs products to the SCU 300 8 4 5 TRAINING MODE Training mode is a test mode The training mode allows the user to test which placement of the SCU 300 is the best for the current situation 8 4 6 SCU PLACEMENT Set where you want to place the SCU 300 Select between chest position recommended or w...

Страница 12: ...d to the Tactical Modular Audio System 8 4 17 FACTORY RESET Reset the SCU 300 to the original settings 9 TROUBLESHOOTING Problem Solution The SCU 300 will not power on Make sure the batteries are inserted correctly Make sure there are fully charged batteries in the SCU 300 The SCU 300 will not send and or receive radio communications Check the cable connection to the radio and the SCU A voice mess...

Страница 13: ... user automatically exits the menu if no button is pressed for 10 seconds I cannot control the system with the RCU 300 Make sure there are fully charged batteries in the SCU 300 Check the battery level of the RCU 300 Refer to 8 4 1 Battery status Pair the SCU 300 to the RCU 300 Refer to 6 6 To pair the RCU 300 to the SCU 300 Make sure that you are using the correct RCU 300 Make sure the RCU 300 is...

Страница 14: ...44 1 3M PELTOR Spring steel bracket RCU 300 DE0408 1 3M PELTOR Battery cap kit TKD8003 1 3M PELTOR SCU Attachment clip For more information about spare parts and accessories please contact 3M Technical Services Refer to contact information listed on the last page of this manual 13 WARRANTY AND LIMITATION OF LIABILITY NOTE The following statements do not apply in Australia and New Zealand Consumers...

Страница 15: ...nte por la parte responsable del cumplimiento podrían anular la autoridad del usuario para operar el equipo Este dispositivo cumple con la Parte 15 de las Reglas de la FCC La operación está sujeta a las siguientes dos condiciones 1 este dispositivo no puede causar interferencia perjudicial y 2 este dispositivo debe aceptar cualquier interferencia recibida incluida la interferencia que puede causar...

Страница 16: ...ar PTT II Q Botón SCU 300 A Conector de intercomunicador B Conector de orejera C Conector de radio 1 D Conector de radio 2 E Botón de pulsar para hablar PTT I F Botón de pulsar para hablar PTT II G Botón H Botón I Botón On Off Menu encender apagar menú J Botón de función K Tapa de compartimento de baterías L Broche metálico 4 SINOPSIS ES ...

Страница 17: ... emparejamiento correcto con cada dispositivo Ver 6 7 Para montar SCU 300 2 Mantener presionado el botón On Off Menu del SCU 300 durante 3 segundos ON 3 sec 2 sec OFF 3 El dispositivo TEP 300 o ComTac VII indicará el emparejamiento 2 pitidos cortos indican el emparejamiento correcto de la SCU 300 3 pitidos largos indican que se ha perdido la conexión de NFMI Beep Beep Beeeep Beeeep Beeeep Nota Los...

Отзывы: