![3M Nanolock 3101214 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/3m/nanolock-3101214/nanolock-3101214_instruction-manual_443928013.webp)
13
Figure 11 – 100% Tie-Off
Figure 12 – Incorrect Attachment
4.7 AERIAL WORK PLATFORMS:
Use of the Nano-Lok SRL on aerial work platforms is permissible, provided
the following criteria are met:
1. Nano-Lok SRLs generally will not restrain workers from falling out of aerial work platforms or elevated
working surfaces. To restrain users from falling out of aerial work platforms, Positioning Lanyards of
sufficiently short lengths should be used.
2. Aerial work platforms must have guardrails or gates at all accessible edges along their perimeter unless
anchorages for the Nano-Lok SRLs are located overhead. The edges on the top rails of all guardrails and
gates over which the user might fall must have a minimum radius of 1/8 in. (0.3 cm).
3. Anchorages of appropriate strength and compatibility must always be used for securing Nano-Lok SRLs
(see Section 2).
4. Swing fall hazards may exist, especially when working near corners or out away from anchorage points.
Added fall clearance is needed where the potential for swing fall exists (see Figure 3).
5.
All sharp edges which the Nano-Lok SRL’s lifeline may contact during a fall must be eliminated or
covered over. All edges the SRL lifeline may contact in a fall must be smooth with an edge radius of 1/8
in. (0.3 cm) or greater. Potential pinch points between adjacent surfaces where the lifeline may catch
during a fall must be eliminated.
4.8 HORIZONTAL SYSTEMS:
In applications where the Nano-Lok SRL is used in conjunction with a horizontal
system (i.e. Horizontal Lifeline, Horizontal I-Beams Trolley), the SRL and horizontal system components
must be compatible. Horizontal systems must be designed and installed under the supervision of a qualified
engineer. Consult the horizontal system equipment manufacturer’s instructions for details.
5.0 INSPECTION
5.1 RFID TAG:
The Nano-Lok SRL includes a Radio Frequency
Identification (RFID) tag. The RFID tag can be used in
conjunction with the handheld reading device to simplify
inspection and inventory control and provide records for your
fall protection equipment. If you are a first-time user, contact
a 3M Fall Protection Customer Service representative, (see
back cover). Follow the instructions provided with your RFID
handheld reader or software to transfer your data to your
database.
Figure 13 – RFID Tag
5.2 INSPECTION FREQUENCY:
The Nano-Lok SRL must be inspected at the intervals defined in “
Section 2.5 -
Inspection Frequency”
. Inspection procedures are described in the
“Inspection Checklist”
(Table 2).
5.3 UNSAFE OR DEFECTIVE CONDITIONS:
If inspection reveals an unsafe or defective condition, If
inspection reveals an unsafe condition, remove the SRL from service, mark
“UNUSABLE”,
and dispose of in
the recommended manner (see
“Section 5.5 - Disposal”
).