Multimedia Projector MP8660
A–8. Serial Interface Command Codes,
continued
Function
Code
Meaning
Blue panel position
Write Codes
D59W00
D59W01
D59W02
Read Codes
D59R
Sets the blue panel to center
Sets the blue panel by 1 pixel up
Sets the blue panel by 1 pixel down
Returns:
00–Blue panel is in center position
01–Blue panel moves 1 pixel up
02–Blue panel moves 1 pixel down
IR receiver selection
Write Codes
D5AW00
D5AW01
D5AW02
Read Codes
D5AR
Selects Front and Rear IR Receiver
Selects Front IR Receiver
Selects Rear IR Receiver
Returns:
00–Front and Rear Receiver is selected
01–Front receiver is selected
02–Rear receiver is selected
Lamp Timer Reset
Write Codes
D60W00
Read Codes
D60R
Resets the lamp timer
Returns:
xxxx–shows lamp operating time in hours (decimal)
Temperature
Read Codes
D61R
Returns:
Shows the status of internal temperature
00–Temperature level 0
01–Temperature level 1
02–Temperature level 2
03–Temperature level 3
04–Temperature level 4
05–Temperature level 5
06–Temperature level 6
Reset
Write Codes
D62W00
Resets all settings to default
Error Status
Read Codes
D01R
Returns:
00–No error
01–Interlock error
02–Lamp error
04–Temperature error
08–Fan error
10–Memory error
Note: If there is more than one error, the resulting read code will
be the sum of the error codes listed above. Example: For