Serial Command Codes
All numbers in this document are in Hexadecimal. You must send at the same communication setting
as the projector and use a null modem serial cable to connect to the projector.
There are four types of messages for the MP8730, 1) ASK, 2) REPLY, 3) SET and 4) DEFAULT.
Ask Code:
User:
20
XX
XX is the attribute you are checking.
Projector:
1Y
XX
Y bytes of data
This is a reply code. The Y is the number of extra bytes that come after the command.
The XX is the same as in the Ask code.
Set Code:
User:
3Y
XX
Y bytes of data
XX is the attribute you are checking. The Y is the number of bytes for the data.
Projector:
1Y
XX
Y bytes of data
This is a reply code. The Y is the number of extra bytes that come after the command.
The XX is the same as in the Set code.
Default Code:
User:
40
XX
XX is the attribute you are checking.
Projector:
1Y
XX
Y bytes of data
This is a reply code. The Y is the number of extra bytes that come after the command.
The XX is the same as in the Ask code.
Errors:
For an error, the projector will reply with the same code that was sent but with a 0 in the first nibble.
A.9
Содержание Multimedia Projector MP8625
Страница 3: ...D o w n l o a d e d f r o m P r o j e c t o r c o m ...
Страница 5: ...D o w n l o a d e d f r o m P r o j e c t o r c o m 3M Multimedia Projector MP8625 3M 1998 ENGLISH ...
Страница 35: ...D o w n l o a d e d f r o m P r o j e c t o r c o m 3M Multimedia Projector MP8625 3M 1998 TECHNICAL A 12 ...
Страница 36: ...D o w n l o a d e d f r o m P r o j e c t o r c o m ...