1.0 Description
The 3M
™
Mini Air Ionizer 960 is a self-contained ionizing air blower designed
to remove static charges from non-conductive objects. The proprietary circuitry
contained in the blower generates balanced levels of positive and negative ions,
and maintains correct balance despite variations in line voltage, fan speed, and
emitter point condition.
2.0 Performance
The Mini Air Ionizer 960 reduces a static charge of 1000V to 100V in less than
6 seconds (the discharge time) at a distance of 1 foot. Testing is performed in
accordance with the ESD Association ionization standard ANSI/ESD S3.1. Ion
balance variation is within 20 volts of zero at a distance of 1 foot.
3.0 Power Requirements
The Mini Air Ionizer 960 requires AC 24V power, supplied through a RJ-11
power socket located on the back of the unit. The 3M
™
Transformer 960/980X,
available as a separate item, is used to supply power to the Mini Air Ionizer 960
via a phone cable with an RJ-11 connector. It is possible to connect four (4) Mini
Air Ionizer 960’s together in series and power them off of one (1) Transformer
960/980X.
To reduce the risk of electric shock, the Transformer 960/980X uses a grounding
plug that has a third (grounding) pin. This plug will only fit into a grounding-
type power outlet. If the plug does not fit into the outlet, contact qualified
personnel to install the proper outlet. Do not alter the plug in any way. If an
alternate power source is used, please make sure that it conforms to the power
input requirements as listed in the Specifications section. For further questions
concerning the power-input requirements, please feel free to contact 3M
Technical Service.
4.0 Installation
The Mini Air Ionizer 960 mounts easily in a variety of positions using the
provided tilting bracket/stand. Place the unit on the work surface and point it at
the area or object to be neutralized. Alternatively, the mounting bracket may be
attached directly to or above the workstation, or on another supporting structure.