3M Touch Systems, Inc. Proprietary Information
1 false touch allowed
±20KV Air Discharge – Class 1 per section 9 of IEC 61000-4-2
Compliant
Normal Operation – No false touches
MTBF (by MIL Std. 217F Calculation)
>400,000 Hours
3M Touch Systems Parameters
Accuracy vs. Dynamic Temperature Change
Maintains 1% Accuracy
(tested at 0
°
C to 65
°
C with a 0.5
°
C/minute temperature ramp)
Communications
Protocol
USB
Rev
1.1
Figure 4. Storage and Operating Temperature and Humidity Conditions