Table 19. Reset Request
Offset
Field
Size
Value
Description
0
bmRequestType
1
0x21
Host to device
1 bRequest 1
0x09
Set
Report
2
wValue
2
0x0303
03 = Feature
03 = Feature Report ID
4 wIndex
2
0 Always
0
6 wLength 2
8 Always
8
Table 20. Data Stage
Offset
Field
Size
Value
Description
0
bReport ID
1
0x03
Host to device
1
bmReport Subtype 1
0x07
Indicates a reset request
2 bResetType
1
0xXX
0x01=Soft
reset
3 Not
used 5
0 Not
used
Response
The device stalls endpoint 0 if the request cannot be processed successfully. The request
cannot be processed if the reset type specified by the bResetType field is not valid.
Set Feature - Restore Defaults
This is a request to restore the default values in the controller to the factory presets. You
must recalibrate after this command since this request will also default the calibration and
display orientation.
Table 21. Restore Defaults Request
Offset
Field
Size
Value
Description
0
bmRequestType
1
0x21
Host to device
1 bRequest
1 0x09 Set
Report
2
wValue
2
0x0303
03 = Feature
03 = Feature Report ID
4 wIndex
2 0
Always
0
6 wLength
2 8
Always
8
Table 22. Data Stage
Offset
Field
Size
Value
Description
0
bReport ID
1
0x03
Feature Report ID
1
bmReportSubtype
1
0x08
Indicates a restore defaults request
2
Not used
6
0
Not used