3M™ MicroTouch™ Controller EX Dual Mode Reference Guide
45
3M Touch Systems, Inc. Proprietary Information – TSD-40848A
Storage Humidity Range
< 36°C 0-80% RH
≥
36
°
C (refer to Figure 3)
Performance and Reliability
Minimum Touch Duration
5.4 msec.
Touch Resolution – (Maximum addressable coordinates generated by the
controller)
16K x 16K
ESD Susceptibility
1
-
±
8 kV Contact Discharge – Class 2 per section 9 of IEC 61000-4-2
1 false touch allowed
Compliant
±
27 kV Air Discharge – Class 1 per section 9 of IEC 61000-4-2
Normal Operation – No false touches
Compliant
MTBF (by MIL Std. 217F Calculation)
740, 000 Hours
Touch System Parameters
Accuracy vs. Dynamic Temperature Change
(tested at 0 deg. C to 60 deg. C with a 0.5 deg. C/minute
temperature ramp)
Maintains 99.0% Accuracy
Sensor Compatibility
3M™ MicroTouch™ Capacitive Sensors
Communications Protocol
USB or serial RS 232
Figure 3. Storage and Operating Temperature with Humidity Conditions
1
ESD discharges to a 3M™ MicroTouch™ sensor connected to the controller