3M™ MicroTouch™ Controller EX Serial Reference Guide
35
3M Touch Systems, Inc. Proprietary Information -- 29087v03
AS/NZS 3548:1995/CISPR 22 Class B ITE
Emissions (Aus.)
Class B
Compliant
RFI – EN 61000-4-3 / ENV 50140
Class A
Compliant
CRFI – EN 61000-4-6
N/A
Cable < 3 meters long
Class A
< 80% Screen Area
Class
B
≥
80% Screen Area N/A
EFT (Burst Immunity) – EN 61000-4-4
Class B
Compliant
ESD Susceptibility – IEC 61000-4-2
Class 1
Compliant
Surge – EN 61000-4-5
Class B
Compliant
Harmonics – EN 61000-3-2
Class A
Compliant
Flicker – EN 61000-3-3
Compliant
Power Frequency Magnetic Field – EN 61000-4-8
Class
A
Compliant
Voltage Dips – EN 61000-4-11
Class B
< 5% V
Class C
< 70% V
Compliant
Voltage Interruptions – EN 61000-4-11
Class C
Compliant
UL/cUL
Compliant
Ambient Operating and Storage Environmental Conditions
Note:
All humidity is non-condensing
Operating Temperature Range
-40
C to +70
C
Operating Humidity Range
< 36° C 0-95% RH
≥
36
C (refer to Figure 4)
Storage Temperature Range
-50
C to +85
C
Storage Humidity Range
< 36°C 0-80% RH
≥
36
C (refer to Figure 4)
Performance and Reliability
Minimum Touch Duration
5.4 msec.
Touch Resolution – (Maximum addressable coordinates generated by the
controller)
16K x 16K