background image

1

GENERAL SAFETY INFORMATION

 .......................................................2

 

Intended Use ..................................................................................2

 

List of Warnings and Cautions ........................................................2

USE INSTRUCTIONS AND LIMITATIONS

 ..............................................3

 

Use For ..........................................................................................4

 

Do Not Use For ...............................................................................4

 

General Description........................................................................4

 Features.........................................................................................5

 Specifications ................................................................................5

INSTALLATION AND OPERATION INSTRUCTIONS

 ...............................5

 Location .........................................................................................5

 Installation .....................................................................................6

 

Power Up .......................................................................................8

 Operation .......................................................................................8

 Alarms ...........................................................................................8

 

Reset/Silence Switch .....................................................................9

 

Trouble Indicator ..........................................................................10

 Errors ...........................................................................................10

MAINTENANCE

 ..................................................................................10

 Testing .........................................................................................10

 Cleaning ......................................................................................11

 

Sensor Poisons ............................................................................11

3M™ GAS DETECTION PRODUCTS WARRANTY

 ...............................11

TABLE OF CONTENTS

Содержание Macurco CM-16A

Страница 1: ...ser Instructions may adversely affect product performance and result in sickness or death For proper use see User Instructions or call 3M in U S A 1 800 243 4630 In Canada call Technical Service at 1 800 267 4414 Important Keep these User Instructions for reference FOR MORE INFORMATION In United States contact Website www 3M com OccSafety Technical Assistance 1 800 243 4630 For other 3M products 1...

Страница 2: ...ot Use For 4 General Description 4 Features 5 Specifications 5 INSTALLATION AND OPERATION INSTRUCTIONS 5 Location 5 Installation 6 Power Up 8 Operation 8 Alarms 8 Reset Silence Switch 9 Trouble Indicator 10 Errors 10 MAINTENANCE 10 Testing 10 Cleaning 11 Sensor Poisons 11 3M GAS DETECTION PRODUCTS WARRANTY 11 TABLE OF CONTENTS ...

Страница 3: ...l Safety and Health Administration OSHA commercial or industrial standards To help avoid false alarms the CM 16A is not intended for low level detection below 30 ppm of carbon monoxide per UL 2034 Individuals with certain medical problems may consider using warning devices that provide audible and visual signals for carbon monoxide concentrations below 30 ppm The following symptoms are related to ...

Страница 4: ...Monoxide CO The CM 16A is NOT designed to detect smoke fire or any other gas Do NOT mount the unit in the garage Do NOT mount the CM 16A where the normal ambient temperature is below 40 F 4 4 C or exceeds 100 F 37 8 C or within 5 feet 1 5 meters of a cooking or heating appliance The Alarm Control Panel must be dedicated to CO detection or have alarm devices that provide a distinctive alarm for car...

Страница 5: ...two screws inside the CM 16A s mount on a two gang old work box or a 4 X 4 electrical box provided by the installer 2 The detector may be installed on either a ceiling or a wall If installed on a peaked gabled or sloped ceiling it should be located about 3 feet from the highest point The unit can be placed vertically or horizontally on a wall so the information on the front of the CM 16A can be re...

Страница 6: ...are aware they are not well they become so disoriented they are unable to save themselves by either exiting the building or calling for assistance Young children and household pets may be the first affected Transient CO situations can occur 1 Excessive spillage or reverse venting of fuel burning appliances caused by outdoor ambient conditions such as a Wind direction and or velocity including high...

Страница 7: ... CM 16A status indicator light is illuminated GREEN continuously If not do not proceed with the tests Though there is no field calibration procedure for this unit there is an optional field test procedure CLEANING The CM 16A should be cleaned using the soft brush attachment of your vacuum cleaner The CM 16A should be tested after cleaning to ensure the unit is operating normally SENSOR POISONS The...

Отзывы: