3. Re-wire Lane1 - Speaker, Microphone,  Induction Loop  to G5 Basestation

Follow the illustration below to wire the Order Point Speaker, Microphone and Induction Loop, ,and Monitor Speaker (if applicable).

NOTE: 

If the current wires do not extend out to the terminals on the G5 Basestation, you may splice in sufficient length of wire from an 

another spool of 3M Cables. 
Make sure the point where you connect the two wires (or splice) is properly insulated with Electrical Insulation Tape and/or securely held 
with wire nuts. This ensures against any accidental grounding of the wires.

5

Содержание G5

Страница 1: ...pecting the XT 1 basestation for all connected peripherals Timers Greeters External or Inspecting the XT 1 basestation for all connected peripherals Timers Greeters External or Internal Vehicle Detect...

Страница 2: ...der Taking Modes SPLIT CROSS or DAY NIGHT 7 Alert Message Re wiring 8 Power up the G5 Basestation 9 Register G5 and or XT 1 Headsets 10 Connecting to G5 Basestation Web Server for configuration 11 Con...

Страница 3: ...the XT 1 Basestation Blue White Order Point Speaker Red Black Shield Order Point Microphone GND Green Yellow Loop terminals on Vehicle Detector board If using Internal Vehicle Detector Disconnect any...

Страница 4: ...p and Timer Greet Event wires Once this is completed you will need to drill the remaining two holes to secure Venus basestation to the wall NOTE If the current cable lengths terminating on the XT 1 Ba...

Страница 5: ...pplicable NOTE If the current wires do not extend out to the terminals on the G5 Basestation you may splice in sufficient length of wire from an another spool of 3M Cables Make sure the point where yo...

Страница 6: ...s the same on both boards the left pin on one corresponds to the left pin on the other Configure the dip switches if required according to the table on the circuit board and your needs Lane 1 Lane 2 D...

Страница 7: ...XT 1 Basestation s Menu Board Speaker terminals MEN SKR and MEN SKR To extract the Greet Event from the G5 Basestation connect the wires from the Timer system to GPIO11 and GND1 as illustrated NOTE GE...

Страница 8: ...ack an Alert message whenever an external event occurs such as Opening the Back Door or Opening the Refrigerator You can configure any of the 16 GPIOs on the G5 Basestation Model as ALERT Message Trig...

Страница 9: ...asscode protected area that contains most of the configuration options for the G5 Basestation system Using the access provided for users it is possible to set up all of the functionality of the system...

Страница 10: ...the 3M product and determining whether it is fit for user s particular purpose and suitable for user s method of application Warranty Limited Remedy and Disclaimer 3M warrants that its intercom produc...