3M Flexiguard 8517760 Скачать руководство пользователя страница 4

FORM NO: 5908278  REV: A

4

SAFETY INFORMATION

Please read, understand, and follow all safety information contained in these instructions prior to the use of this Flexiguard System. 

FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY OR DEATH.

These instructions must be provided to the user of this equipment. Retain these instructions for future reference.

Intended Use:

This Flexiguard System is intended for use as part of a complete fall protection or rescue system.

Use in any other application including, but not limited to, material handling, recreational or sports related activities, or other activities not described in 

the User Instructions, is not approved by 3M and could result in serious injury or death.

This system is only to be used by trained users in workplace applications.

 

!

WARNING

This Flexiguard System is part of a personal fall protection or rescue system. It is expected that all users be fully trained in the safe installation and 

operation of the complete system. 

Misuse of this system could result in serious injury or death.

 For proper selection, operation, installation, 

maintenance, and service, refer to all Product Instructions and all manufacturer recommendations, see your supervisor, or contact 3M Technical Service.

• 

To reduce the risks associated with transporting a Flexiguard system which, if not avoided, could result in serious injury or death:

 

-

Ensure the system is properly secured or configured prior to transport. Refer to the User Instructions for detailed transportation requirements.

 

-

Only transport below 5 mph (8 km/h) and at inclines of 10° or less, or as outlined in the User Instructions.

 

-

Ensure the system will not contact overhead objects or electrical hazards while transporting or in use.

• 

To reduce the risks associated with working with a Flexiguard system which, if not avoided, could result in serious injury or death:

 

-

Inspect all components of the system before each use, at least annually, and after any fall event, in accordance with the User Instructions.

 

-

If inspection reveals an unsafe or defective condition, remove the system from service and repair or replace according to the User Instructions.

 

-

Any system that has been subject to fall arrest or impact force must be immediately removed from service. Refer to the User Instructions or 

contact 3M Fall Protection.

 

-

The substrate or structure on which the system is attached/positioned must be able to sustain the static loads specified for the system in the 

orientations permitted in the User Instructions or Installation Instructions.

 

-

Do not exceed the number of allowable users as per the User Instructions.

 

-

Never attach to a system until it is fully assembled, positioned, adjusted, and installed. Do not adjust the system while a user is attached.

 

-

Never work outside the safe work area as defined by the User Instructions.

 

-

Do not connect to the system while it is being transported or installed.

 

-

Always maintain 100% tie-off when transferring between anchor points on the system.

 

-

Use caution when installing, using, and moving the system as moving parts may create potential pinch points.

 

-

Ensure proper lockout/tagout procedures have been followed when applicable.

 

-

Only connect fall protection subsystems to the designated anchorage connection point on the system.

 

-

When drilling holes for assembly or installation of the system, ensure no electric lines, gas lines, or other critical materials or equipment will be 

contacted by the drill.

 

-

Ensure that fall protection systems/subsystems assembled from components made by different manufacturers are compatible and meet the 

requirements of applicable standards, including the ANSI Z359 or other applicable fall protection codes, standards, or requirements. Always 

consult a Competent or Qualified Person before using these systems.

• 

To reduce the risks associated with working at heights which, if not avoided, could result in serious injury or death:

 

-

Ensure your health and physical condition allow you to safely withstand all of the forces associated with working at height. Consult with your 

doctor if you have any questions regarding your ability to use this equipment.

 

-

Never exceed allowable capacity of your fall protection equipment.

 

-

Never exceed maximum free fall distance of your fall protection equipment.

 

-

Do not use any fall protection equipment that fails pre-use or other scheduled inspections, or if you have concerns about the use or suitability 

of the equipment for your application. Contact 3M Technical Services with any questions.

 

-

Some subsystem and component combinations may interfere with the operation of this equipment. Only use compatible connections. Consult 

3M prior to using this equipment in combination with components or subsystems other than those described in the User Instructions.

 

-

Use extra precautions when working around moving machinery (e.g. top drive of oil rigs) electrical hazards, extreme temperatures, chemical 

hazards, explosive or toxic gases, sharp edges, or below overhead materials that could fall onto you or the fall protection equipment.

 

-

Use Arc Flash or Hot Works devices when working in high heat environments.

 

-

Avoid surfaces and objects that can damage the user or equipment.

 

-

Ensure there is adequate fall clearance when working at height.

 

-

Never modify or alter your fall protection equipment. Only 3M or parties authorized in by 3M may make repairs to the equipment.

 

-

Prior to use of fall protection equipment, ensure a rescue plan is in place which allows for prompt rescue if a fall incident occurs.

 

-

If a fall incident occurs, immediately seek medical attention for the fallen worker for the worker who has fallen.

 

-

Do not use a body belt for fall arrest applications. Use only a Full Body Harness. 

 

-

Minimize swing falls by working as directly below the anchorage point as possible.

 

-

If training with this device, a secondary fall protection system must be utilized in a manner that does not expose the trainee to an unintended 

fall hazard.

 

-

Always wear appropriate personal protective equipment when installing, using, or inspecting the device/system.

EN

Содержание Flexiguard 8517760

Страница 1: ... 3M 2019 FORM NO 5903228 REV F USER INSTRUCTION MANUAL Fall Arrest System Model Numbers 8517760 8517761 8517762 8517763 1 G E J I H J F F A B C C C C E D D ...

Страница 2: ... 11 0 3 4 11 2 3 4 11 4 3 5 11 7 3 6 12 1 3 7 12 5 3 8 12 3 7 12 0 3 7 12 0 3 7 12 2 3 7 12 4 3 8 12 6 3 9 13 0 4 0 13 4 4 1 13 4 0 13 0 4 0 13 0 4 0 13 2 4 0 13 3 4 1 13 6 4 1 13 9 4 2 14 3 4 4 14 4 3 14 0 4 3 14 0 4 3 14 1 4 3 14 3 4 4 14 6 4 4 14 9 4 5 15 2 4 6 15 4 6 15 0 4 6 15 0 4 6 15 1 4 6 15 3 4 7 15 5 4 7 15 8 4 8 16 2 4 9 16 4 9 16 0 4 9 16 0 4 9 16 1 4 9 16 3 5 0 16 5 5 0 16 8 5 1 17 1...

Страница 3: ...3 4 5 6 A B C D E F G A B C 7 W L 8522028 2 77 70 36 mm 6 50 165 10 mm ...

Страница 4: ...ff when transferring between anchor points on the system Use caution when installing using and moving the system as moving parts may create potential pinch points Ensure proper lockout tagout procedures have been followed when applicable Only connect fall protection subsystems to the designated anchorage connection point on the system When drilling holes for assembly or installation of the system ...

Страница 5: ...ions Capacity 2 person up to 310 lbs 141 kg each Anchorage Structure supporting the Counterweight Trailer Fall Arrest System must withstand a 15 500 lb 68 9 kN vertical load Offset 8 ft 2 43 m Total System Weight Approximately 11 850 lb 5 375 kg with Concrete Approximately 5 050 lbs 2 291 kg with concrete removed Counterweight Required Min 6 800 lbs 3084 4 kg Recommended two 4000 psi 27 6 Mpa conc...

Страница 6: ...k if a fall occurs Working on slowly shifting material such as sand or grain may not allow enough speed buildup to cause the SRL to lock 2 4 HAZARDS Use of this equipment in areas with environmental hazards may require additional precautions to prevent injury to the user or damage to the equipment Hazards may include but are not limited to heat chemicals corrosive environments high voltage power l...

Страница 7: ...sure all connections are compatible in size shape and strength Do not use equipment that is not compatible Ensure all connectors are fully closed and locked 3M connectors snap hooks and carabiners are designed to be used only as specified in each product s user s instructions See Figure 6 for examples of inappropriate connections Do not connect snap hooks and carabiners A To a D ring to which anot...

Страница 8: ...ly below the Anchorage Connection Point to minimize Swing Fall The angle of the Self Retracting Lifeline should never be more than 30 from vertical and the Horizontal Distance between the anchorage connection point and the worker should not be greater than 6 ft 1 82 m 4 2 USING THE COUNTERWEIGHT HORIZONTAL RAIL SYSTEM Step 1 Position the Counterweight Horizontal Rail System over the desired work a...

Страница 9: ...g by 3M may make repairs to this equipment 6 3 PRODUCT LIFE The functional life of the Fall Arrest System is determined by work conditions and maintenance As long as the product passes inspection criteria it may remain in service 7 0 MAINTENANCE SERVICING STORAGE 7 1 CLEANING Periodically clean the Fall Arrest System s metal components with a soft brush warm water and a mild soap solution Ensure p...

Страница 10: ... WITH RETRACTABLE DEVICES AND SHOCK ABSORBERS WITH A MAXIMUM ARRESTING FORCE M A F RATING OF 900 lb 4kN OR LESS TRANSFERRING FROM ONE SRL TO ANOTHER MUST BE DONE SO YOU ARE ATTACHED TO AT LEAST ONE SRL AT ALL TIMES NO MORE THAN ONE PERSON MAY BE ATTACHED TO A GLIDE RAIL TROLLEY AT ANY GIVEN TIME SEE BELOW TO DETERMINE THE MAXIMUM NUMBER OF PERSONS ABLE TO USE THIS SYSTEM NEVER EXCEED THE MAXIMUM U...

Страница 11: ...are securely attached and are legible See Labels PFAS and Other Equipment Additional Personal Fall Arrest System PFAS equipment harness SRD etc that are used with the Flexiguard Anchorage System should be installed and inspected per the manufacturer s instructions Serial Number s Date Purchased Model Number Date of First Use Corrective Action Maintenance Approved By Date Corrective Action Maintena...

Страница 12: ... 7 29 Kitashinagawa Shinagawa ku Tokyo Phone 81 570 011 321 Fax 81 3 6409 5818 psd jp mmm com WEBSITE 3M com FallProtection I S O 9 0 0 1 FM534873 EU DECLARATION OF CONFORMITY 3M com FallProtection DOC U S PRODUCT WARRANTY LIMITED REMEDY AND LIMITATION OF LIABILITY WARRANTY THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OR CONDITIO...

Отзывы: