175
3M™ Dynatel™ Advanced Modular System 965AMS
Specifications
Electrical Specifications
Functions
Range
Resolution
Accuracy
Tone output
ID tone
Precision tone-
600
7
Zout
200 to 1000 Hz,
fixed level
200 to 9999 Hz,
-20 to +1 dBm
10 k to 19.99 kHz,
-20 to +1 dBm
8 volt peak to peak
1 Hz, 0.1 dB
1 Hz, 0.1 dB
+1 Hz
1% Hz, 0.2 dB
2% Hz, 1 dB
Ringers
0.0 to 4.0 ringer
0 to 2000 nF
0.1 ringer
10 nF
Load coil count
0 to 5
1
±1 load coil
Ground resistance
5 to 500
7
1
7
1% ± 1
7
Ohms/distance
calculator
0-9999
7
0-99999 ft (0-30 km)
0.01
1 ft (0.1 m)
—
—
TDR
Ranges
100 ft, 200 ft,
500 ft, 1,000 ft,
2,000 ft, 5,000 ft,
10,000 ft, 20,000 ft,
30,000 ft (30 m, 60 m,
150 m, 300 m, 600 m,
1.5 km, 3km, 6 km,
10 km)
1 ft (1 m)
5 nS, 34 nS, 135 nS,
1660 nS, 600 nS
*
0.3% range
Fixed values
Velocity input
0.50 to 0.99
(150 to 299 m/µs)
—
—
Modes
Single trace, dual
trace, differential,
memory, crosstalk,
peak, memory diff.
—
—
Loss
(and frequency)
With 600
7
Zin
-40 to +10 dBm, 200
to 3000 Hz,
-40 to +10 dBm, 3000
to 9995 Hz,
-40 to +10 dBm, 10 k
to 19.9 kHz
0.1 dB, 1 Hz,
0.1 dB, 10 Hz
1 dB, 10 Hz
±0.5 dB, 2 Hz
±0.5 dB, 10 Hz
±1 dB, 20 Hz
Dynatel 965AMS-BT.indd 175
6/21/06 10:49:25 AM
Содержание Dynatel 965AMS
Страница 57: ......