Measurement Functions
Auto Test>
Vacant Wideband
Use
Vacant Wideband
to perform an automatic sequence
of tests on Vacant Wideband circuits. The tests include: DC
Voltage, AC Voltage, DC Resistance, Opens, % Capacitance
Balance, Load Coil, Voice Band Loss, Voice Band Noise, Power
Influence, Longitudinal Balance, Slope, Resistance Balance
(loop) and Resistance Balance (% diff).
Note: You must use a 3M FED to use the Vacant WideBand
function.
Insertion Loss Frequencies and Sweep Frequencies by Service Type
Insertion
Loss
Sweeps
Single
Frequency*
Sweep Frequencies
Pots
1004 Hz
404, 804, 1004, 1204, 1404, 1604, 1804, 2004,
2804, 3004 (Hz)
56k
28 kHz
20, 28, 32, 40, 48, 82 (kHz)
64k
32 kH
z
20, 28, 32, 40, 48, 82 (kHz)
ISDN
40 kHz
20, 28, 32, 40, 48, 60, 70, 82 (kHz)
HDSL
196 kHz
20, 30, 50, 70, 90, 110, 130, 196, 400 (kHz)
T1
772 kHz
200, 400, 500, 700, 772, 1024 (kHz)
E1
1024 kHz
200, 400, 500, 700, 772, 1024 (kHz)
ADSL
138 kHz
20, 30, 50, 69, 90, 110, 138, 276, 400, 600,
800, 1000, 1100 (kHz)
H2/4ACC
196 kHz
50, 80, 130, 196, 250, 300, 350 (kHz)
H4RACC**
N/A
20, 30, 50, 70, 90, 110, 130, 196, 400 (kHz)
H4NACC***
N/A
20, 30, 50, 70, 90, 110, 130, 196, 400 (kHz)
* Pass/Fail provided for Single Frqeuency when measuring just Single Frequency or in Sweep Mode.
** Pass/Fail provided for 50 kHz, 90 kHz and 130 kHz
*** Pass/Fail provided for 50 kHz, 90 kHz, 130 kHz and 196 kHz